Refer to "4.7.3 Database" for human target database settings information.
Step 8 Configure the parameters. See Table 4-36.
Parameter
Period
Alarm-out Port
Post-Alarm
Report Alarm
Send Email
Figure 4-130
Table 4-37
Description
Configure the period and in the set time range, the corresponding configuration item
will be linked to start the alarm.
The alarm device (such as lights, sirens, etc.) is connected to the alarm output port.
When an alarm occurs, the NVR device transmits the alarm information to the alarm
device.
When the alarm ends, the alarm extended for a period of time. The time range is
from 0 seconds to 300 seconds.
Select the check box. When an alarm occurs, the NVR device uploads an alarm
signal to the network (including the alarm center).
● This function is for some series products only.
● You need to set the alarm center first. For details, see "4.12.13 Alarm
Center".
Select the check box. When an alarm occurs, the NVR device sends an email to
the set mailbox to notify the user.
You need to set the email first. For details, see "4.12.10 Email".
221