BLUEHELIX PRO C
Fault code Fault
Possible cause
A42
Heating sensor fault
Sensor damaged
No system H
Exchanger protection activa-
F43
tion
Air in the system
DHW sensor detached from
A44
Sensor positioning
pipe
F52
Heating sensor fault
Sensor damaged
Controller internal error
A61
Controller fault ABM03C
ABM03C
Controller not connected
No communication between
A62
controller and gas valve
Valve damaged
A63
F64
Controller internal error
Controller fault ABM03C
A65
ABM03C
F66
A23
A24
F20
F21
Card parameter fault
Wrong card parameter setting
A26
F40
F47

5. TECHNICAL DATA AND CHARACTERISTICS

196
350
81
35
278
221
42
10
8
44
fig. 27 - General view
Cure
Replace the sensor
O circulation
Check the circulating pump
2
Vent the system
Check the correct positioning and
operation of the DHW sensor
Replace the sensor
Check the earth connection and
replace the controller if necessary.
Connect the controller to the gas
valve
Replace the valve
Check the earth connection and
replace the controller if necessary.
Check the card parameter and mod-
ify it if necessary.
7
9
11
39
74
136
37
cod. 3541F553 - Rev. 02 - 09/2018
Table. 9 - Legend - figures cap. 5
7 Gas inlet
8 Domestic hot water outlet
9 Cold water inlet
10 System delivery
11 System return
14 Pressure relief valve
16 Fan
32 Heating circulating pump
35 Air separator
36 Automatic air vent
37 Cold water inlet filter
39 Flow regulator
42 DHW temperature sensor
44 Gas valve
56 Expansion tank
72 Room thermostat (not supplied)
74 System filling cock
81 Ionisation/ignition electrode
191
56
35
278
186
193
14
221
36
114
10
32
94 System cock
104 Fuse
114 Water pressure switch
136 Flow meter
138 External probe (optional)
139 Remote timer control (optional)
154 Condensate drain pipe
186 Return sensor
191 Fume temperature sensor
193 Trap
196 Condensate tray
221 Bypass cock
256 Modulating heating circulating pump signal
278 Double sensor (Safety + Heating)
340 Bypass pipe
350 Fan/Burner assembly
A ON/OFF switch (configurable)
193
154
74
340
39
136
42
37
8
9
fig. 28 - Hydraulic circuit