ROBLIN Vitral 600 Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
INSTALLATION
If the hood is to be connected in the ducting version, with the pipe coming out of the back, re-
member that the air venting duct must be created as indicated in the drawing.
If the hood is fitted in the recirculation version, bear in mind that there must be a minimum dis-
tance of at least 8-10 Cm left between the top of the hood and the surface above it (ceiling or
shelf).
Draw the following on the Wall:
• a Vertical line up to the ceiling or top surface, at the centre of the area in which the Hood is
to be fitted;
• a Horizontal line: 550 mm min. above the Hob;
• As shown in the drawing, mark a reference point 720 mm above the reference horizontal
line, and at a distance of 155 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking to ensure it is level.
• Drill the points marked using a ø 12 mm drill bit.
• Insert the wall plugs with screw and bracket 11a into the holes, tighten.
• As shown in the drawing, mark a reference point 196.5 mm above the reference horizontal
line, and at a distance of 165 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking to ensure it is level.
• Drill the points marked using a ø 8 mm drill bit.
• Insert the plugs 11 into the holes.
EN
Drilling the Wall
Rear air outlet
area
6 6

Publicidad

Tabla de contenido
loading

Tabla de contenido