Troubleshooting - CAMPAGNOLA CLN 0406 Manual De Uso Y Manitenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
ATTENTION!
The batteries supplied by Campagnola memorize the parameters of the charge cycles. A charge cycle
performed by a device being different from the one described in this manual can cause damages and make
any warranty claims become void.
ATTENTION!
Check that the electric network parameters comply with the self-regulation details range of the battery-
charger (see par. 1.3).
Use the battery-charger in a dry and airy room, at a temperature between 10 °C and 40 °C.
Insert the power-supply plug (1) into the electric outlet.
When plugging the battery-charger, the red led (3).
Connect the battery-charger cable (2) to the battery plug. In case of a problem, an alarm sound would indicate it.
The recharge cycle will automatically finish only when the battery is fully loaded. This is indicated by the battery
led that will switch the color from red to green. Then the device will enter the maintenance mode, carrying out
short charging cycles (with red led 3 light) to compensate for the battery self-discharging.
When disconnecting the battery-charger cable (2) from the battery plug, the device will get ready for a new cycle
In any case, it is always advisable, also for power saving reasons, to disconnect the cable when the battery-
charger is not used.
The battery recharge time depends on the cells capacity and the residual charge level.
4. Battery-charger indications
The battery-charger status is indicated by the led (3 - photo A) according to the following indications:
LED (3)
LED battery
1
OFF
OFF
2
RED
RED
3
RED
GREEN
4
RED
GREEN +
ALARM
SOUND

5. Troubleshooting

ATTENTION!
Disconnect the device from the electric network before carrying out any operations.
PROBLEM
The battery-charger does not switch
on (the led 3 light is off)
The battery-charger does not load
(led 1 red, led battery green)
The battery-charger does not load
(The led 3 red, led battery green is
and the sound alarm is on)
6. Maintenance
STATUS
THE BATTERY-CHARGER IS
NOT POWER-SUPPLIED
THE BATTERY-CHARGER IS
POWER-SUPPLIED AND IS
LOADING
THE BATTERY-CHARGER IS
POWER-SUPPLIED, BUT IT
IS NOT LOADING
THE BATTERY-CHARGER IS
POWER-SUPPLIED, BUT IT
IS NOT LOADING
CAUSE
The power-supply cable (1) is
disconnected or damaged
The power-supply fuse (5) is
burnt
The battery is disconnected
The battery is already fully
charged
Burnt charging fuse (4)
11
CAUSES
The power-supply cable (1) is not plugged in the
electric outlet
The power-supply fuse (5) is burnt
The battery is not charged up
The battery is fully charged - The charge
maintenance step is on
The battery is disconnected
Burnt charging fuse (4)
SOLUTION
Connect or replace the power-supply
cable (1)
Replace the fuse (5) – See par.6.1.
Connect the battery to the battery-
charger
Keep the battery in the maintenance
phase or use it
Replace the fuse (4) - (See psar.
6.2)

Publicidad

Tabla de contenido
loading

Tabla de contenido