2. FEATURES (Fig. 1 - 10)
A. I/O Switch (ON/OFF): The I/O switch is the activation mechanism
G
that is used to start and stop the compressor. When the switch is
"On", the motor and pump will compress air until tank pressure
B
reaches the upper limit of the factory set operating pressure.
When tank pressure falls below the factory set "cut in" pressure,
the compressor will again automatically start to compress air.
B. Regulated Pressure Gauge: The regulated pressure gauge
indicates the amount of pressure that is allowed into the discharge
line according to the setting of the regulator.
C. Regulator Knob: The regulator knob is used to adjust the air
pressure that is available at the discharge line. The discharge
air pressure is increased by turning the knob clockwise and
decreased by turning the knob counter clockwise.
D. Drain Valve: Ball style valve that drains moisture from the tank
when opened.
E. Quick Coupler: The quick coupler is used to connect the airline
to your tool.
F. Safety valve: The safety valve is set to avoid over-pressurization
of the air tanks. This valve is factory pre-set and will not function
unless tank pressure reaches this pressure. Do not attempt to
adjust or eliminate this safety device.
Any adjustments to this valve could cause serious injury. If this
device requires service or maintenance, see an Authorized
Service Center.
G. Transportation handle.
H. Rubber foot.
I. Intake air filter.
J. Pressure gauge: It indicates the tank pressure.
K. Wheel.
L. Screw.
M. Nut.
N. Washer.

3. SCOPE OF USE

The compressor is designed for generating compressed air for tools
operated by compressed air.
Please note that our equipment has not been designed for use
in commercial, trade or industrial applications. Our warranty will
be voided if the machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The machine is to be used only for its prescribed purpose. Any other
use is deemed to be a case of misuse. The user/operator and not
the manufacturer will be liable for any damage or injuries of any kind
caused as a result of this.

4. ELECTRICAL GROUNDING INSTRUCTIONS

The compressor is equipped with a mains cable with shock-proof
plug. Insert the plug of the electric cable in a socket of suitable shape,
voltage and frequency complying with current regulations. Before you
use the machine, make sure that the mains voltage complies with the
specifications on the rating plate. Make sure that the ON/OFF switch is
not in the I (ON) position. Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede motor start-up. In the
case of low temperatures below +5°C, motor start-up is jeopardized
as a result of stiffness.
5. PRE-START PROCEDURES
● Examine the machine for signs of transport damage. Report any
damage immediately to the company which delivered the compressor.
● Verify that the tanks have been drained and are clear of any moisture
or dirt.
● The compressor should be set up near the working consumer.
● Avoid long air lines and long supply lines (extensions).
● Make sure the intake air is dry and dust-free.
● Do not set up the compressor in damp or wet rooms.
● The compressor may only be used in suitable rooms (with good
ventilation and an ambient temperature from +5°C to +40°C). There
must be no dust, acids, vapours, explosive gases or inflammable
gases in the room.
● The compressor is designed to be used in dry rooms. It is prohibited
to use the compressor in areas where work is conducted with
sprayed water.
5.1 Fitting the wheel kit
If provided, the wheel kit must be installed as shown in figure 2.
5.2 Fitting the supporting feet
If provided, the rubber feet must be fitted as shown in figure 3.
5.3 Fitting the transport handle (for models
envisaging this)
Screw the transport handle to the compressor as shown in figure 4.
5.4 Fitting the air filter
Remove the transportation stop with a screwdriver or similar and
screw the air filter (ref. I) securely to the equipment (Fig. 5a-5b).
If supplied, insert the suction tube inside the filter cover (Fig. 5c).
5.5 Assembling the quick coupler (if not already
assembled)
Tighten the quick coupler for regulated pressure to the coupling on the
outlet as shown in figures 6a and 6b.
6. OPERATING INSTRUCTIONS
6.1 I/O switch (ON/OFF) (Fig. 7-8)
To switch on the compressor, pull out the knob (ref. A) to position I
(ON).
To switch off the compressor, press the knob (ref. A) in again to
position O (OFF).
6.2 Adjusting the pressure
● You can adjust the pressure on the pressure gauge (ref. B) using the
pressure regulator (ref. C).
● The set pressure can be taken from the quicklock coupling (ref. E).
6.3 Setting the pressure switch
The pressure switch is set at the factory.
● When the upper calibration value (set by the manufacturer) has been
reached, the compressor stops.
When air is used, the compressor restarts automatically when the
lower calibration value is reached.
● The compressor continues to operate according to this automatic
cycle until the I/O switch (ON/OFF) is turned.