Auxiliary function
During a communication with outdoor panel we can activate the aux-
iliary function (light,...) by pressing
Programming mode
During communication with the outdoor panel we can enter/leave
the Outdoor Panel programming mode by pressing:
When we are in programming mode we can configure the following
parameters:
* Lock timing activated from the DECT telephone, pressing the fol-
lowing combination of keys :
1 + n , n is a number from 1 to 9 which indicates
opening time, in seconds (4 seconds by default).
* Lock timing activated from the hallway (egress button), pressing
the following key combination:
2 + n , n is a number from 1 to 9 which indicates
opening time, in seconds (4 seconds by default).
* Auxiliary output activation time, pressing the following key combi-
nation:
3 + n , n is a number from 1 to 9 which indicates
opening time, in seconds (4 seconds by default).
* Outdoor panel speaker volume, pressing the following key combi-
nation:
7 + n , n is a number from 1 to 5 which indicates the
speaker volume level (5 by default).
When we operate with outdoor panel we should take in
consideration:
- Communication with the outside line and other additional tel-
ephones is two-way (full-duplex), whereas with the FERMAX
Outdoor Panel it is one-way (half-duplex), which means that when
you speak you do not hear the interlocutor.
- Communication timing is 80 seconds, which is reset every time
we press a key.