Blanco BC PC 4200 Manual De Uso página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
TABLE OF ALARM INDICATIONS
Alarm
ALL
Thermocouple TCJ has failed or is
Err
The appliance switches to stand-
Er3
Er4
Cause
Safety thermostat with automatic
reset tripped.
not properly connected.
Improper use of the appliance,
such as sudden changes in
temperature (thermal shock).
by status.
Electronic circuit board
diagnostics tripped.
Electronic circuit board heat
sensor tripped.
The appliance switches to
stand-by status.
Fan malfunction.
The appliance switches to
stand-by status.
Air intake line blocked.
The appliance switches to
stand-by status.
- 13 -
Remedy
Allow the appliance to cool and
return it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Important
Contact the after-sales ser-
vice.
Check
the
condition
thermocouple
TCJ
electrical connections.
Allow the appliance to cool
and return it to ON status.
Replace the electronic
circuit board
Important
Contact
the
after-sales
service.
Allow the appliance to
cool and return it to ON status.
Important
If the problem persists, con-
tact the After Sales Service.
Important
Contact the after-sales ser-
vice.
Check the condition of the fan and
the electrical connections.
Clean the air intake lines
Important
If the problem persists, con-
tact the After Sales Service.
of
and
the
IT
GB
DE
FR
ES
English

Publicidad

Tabla de contenido
loading

Tabla de contenido