Technical Data
USD 6
Power Input
Power Output
No load speed
USD 12/11R
USD 6/6R
Wheel capacity
USD 12
USD 6/6R
Sound pressure level
according to CEN/TC 255 N
Vibration according to
ISO/DIS 8662-4
with test disc dia 80x10 <2,5
with test disc dia 100x25
Collets
up to 12 mm
Weight without cord set 2,9
Double Insulated
ClassII
Voltage
various
(refer to Spare parts list)
Machine components
1
Spindle neck
2
Gear housing
3
Collet
4
Clamping nut
5
Open end wrench 22 mm
6
Pin 6 mm
7
On/Off switch
8
Switch lock button
9
Overload cut out switch
10
Variable speed selector
Suitable Tools:
General:If possible always mount shank in
collet until it bottoms out.
USD 12
11
Burs, specialty abrasives,
materials conditioning products
12
Mounted points, Attention: always
observe mounting instructions.
USD 6 / USF 6R
11
Non-woven Nylon Abrasives,
deburring, cleaning and finishing tools
materials conditioning products.
Additional Abrasives and Tools
can be found in the the SUHNER catalogs.
USF 11R
USD 12
USF 6R
750
1000 Watt
500
660 Watt
12'000
5'000-11'000 rpm
6'000
2'500-5,600 rpm
55
55 mm
USF 11R
100
100 mm
USF 6R
85
85 dB(A)
2
<2,5 m/s
up to 12 mm
3/8"
3/8"
3,0 kg
II
various
Safety Instructions:
• Do not exceed max. operating speed of tool
and clamping element.
• Observe accurate mounting of tools.
• Secure work, use clamps or vise to hold
work.
• The grinder operator shall wear safety
goggles or face shield at all times when the
grinder is in operation.
• If noise level exceeds 85 dB(A) at the work
station, sound insulation and hearing
protection measures must be taken by the
operator.
• For additional personal protection, it is
advisable to connect tool to a ground fault
circuit interrupter, (only in damp areas).
• Do not treat any material containing
asbestos.
For additional safety instructions
refer to enclosed brochure EW 39 210 01
Before Start-up
Voltage Warning
Before connecting tool to a power source, be
sure the voltage supplied is the same as
specified on the name plate of the tool. The
power supply should not vary more than 10%
above or below the voltage indicated on the
nameplate.
ON-OFF SWITCH
Before connecting power cord to receptacle,
make sure that switch 7 is in the Off -0-
Position.
Operation conditions and instructions
This tool is equipped with an overload cut-out
switch 9, which cuts out as soon the machine
is overloaded. In this event switch at once to
OFF position, press button 9 after overload
switch has recovered, restart to assure
cooling effect in no load mode. Repeated
automatic cut off indicates, tool is being
overloaded.
Attention: Even if the cut-out is not activated,
danger of overloading always exists, thus
don't
force the tool in order not to increase
unnecessarily excessive current draw, which
overheads the motor.
USF 6R is equipped with an electronic
variable speed tachometer selector and an
overload cut-out switch, which operates as
follows:
1. Soft start
2. With increased work pressure more current
is drawn , which virtually holds speed at a
constant rpm.
3. If the motor is overloaded, the electronic
cuts off the power. In this event switch at once
to OFF position, restart right away to assure
GB