7.1. CLEANING.

In order to clean the lavatory connected to the waste disposer, it is recommended to use any market
high-quality cleaner with no acid components.
In areas with a high level of water hardness and for the purpose of eliminating the lime deposits, it is
recommended to clean regularly the appliance as follows:
- Disconnect the waste disposer from the electrical current.
- Pour into the lavatory a mixture of roughly 1 litre of vinegar and 3 litres of water.
- Leave the mixture to work for some hours.
- Connect the waste disposer again and start it.
7.2. TROUBLESHOOTING GUIDE.
Before performing any operation, please verify the following steps:
- Check that the filling and discharge mechanisms of the lavatory cistern are in good condition, and the
water supply to the cistern remains open.
- Check that the waste disposer in connected to its socket for a proper working, and check it is working
(by checking that the differential has not tripped and the magneto thermal circuit breaker remains
connected)
- Please check the waste disposer thermal disconnection system has not been set in motion (the waste
disposer includes an automatic disconnection system in case of extremely high temperatures), by
waiting roughly 20 minutes (may vary depending on temperature conditions).
- In case of an excessively long operating, or if the waste disposer is started continuously, please check
if there is any sort of leaking from the cistern to the lavatory or in the rest of the connected appliances.
- You must also check that there is no return to the waste disposer through the non-return valve of the
evacuation pipe due to an inappropriate closing thereof (verify that the clappet fits properly). (see repla-
cement-cleaning of the non-return valve on page 26).
PROBLEM
- The waste disposer does not start.
- The differential switch trips.
- The motor works, but does not discharge
or makes it slowly.
- The motor buzzes but does not spin.
- After the evacuation, the motor starts
and stops indefinitely.
- The motor does not stop.
26 - INSTRUCTIONS AND MAINTENANCE GUIDE
REASON
- It is disconnected.
- The electrical connection fails.
- The thermal protection circuit has been
activated.
- Motor earth wire is defective.
- The evacuation pipe is obstructed.
- Turbines or blades blocked by foreign
bodies.
- Escapes in the non-return valve or water
loss from the cistern or from the auxi-
liary connection.
- Evacuation pipe is too high or long for
the diameter of pipe in use.
- Power loss due to too many elbows.
- The discharge pipe is obstructed.
- The discharge pipe is obstructed due to
lime remains.
- The micro-switch does not work properly.
SOLUTION
- Connect the unit properly.
- Check the electrical connection.
- Wait roughly 20 minutes until the motor
cools.
- Motor out of service. Contact the T.A.S.
- Clean the evacuation pipe.
- See the waste disposer dismantling
(page 11)
- Clean the non-return valve of the
discharge pipe.
- Review and replace the joints of the
cistern discharger and those of the taps
from the connected sanitary appliances.
- Review the evacuation installation.
- Review the evacuation installation.
- Perform the descaling process as descri-
bed (cleaning 7.1.)
- Contact the T.A.S.