room the scale powder is left behind. There
are no more hard deposits and residues can be
removed easily with a damp cloth.
cleaning detergents are no longer needed.
Because calmat® is installed on the outside of the pipe
and there is no direct contact with the water, the water
is not chemically altered.
tural elements remain for the human organism. Food
and drinks keep their natural taste.
General advice
calmat® can be used with any pipe material:
Metal pipes: iron, copper, stainless steel, lead,...
Synthetic/plastic pipes: PVC, PE, PP, compound
pipes,...
- calmat® is applicable to pipe cross sections of
max. 3 inch (~.75 mm)
calmat® works most effectively at temperatures
up to 97° C (203° F) surface-contact temperature
- calmat® is absolutely independent from the
velocity of the water
- calmat® functions reliable and has no maintenance
costs
Technical Information
Rated voltage:
Rated input:
Voltage supply:
Impulse cables:
Output:
Dimensions (H/W/D):
Max. pipe-Ø:
Safety instructions
Attention:
Please
read
the
instruction
installing and starting up the system! To avoid causing
damage, please follow these safety instructions:
Harsh
Important minerals and na-
24 V =
4.3 W
100-240 V~ (50/60 Hz)
4 x 5 m
4 x capacitive
180 x 150 x 50 mm
3" (~ 75 mm)
manual
before
- Connect calmat® only to a correct and firmly
installed earthed safety socket (100–240 V~, 50/60 Hz).
- Do not disconnect from power by pulling the wire.
Always disconnect pulling the plug.
- Do not open the electronic unit.
- The exterior temperature where the unit is
installed should be between -10° C until max. +55° C.
- The power plug should be kept away from water drops
and water spray.
- Please clean the unit with a damp cloth only
(no detergents).
- Protect calmat® from direct humidity, water and direct
solar radiation.
Installation instructions
The electronic water treatment system calmat®
prevents scale and rust deposits in pipes and de-
vices. The unit is installed on the main water sup-
ply (e.g. close to the water meter) according to the
following instructions:
- The electronic control unit can be attached
directly on to the pipe. This can be done either hori-
zontally and vertically. It may also be placed
on the wall.
- Wind the impulse cable tightly and firmly without gaps
around the pipe.
- The impulse cable can also be wound on thicker
connecting pieces (e. g. pipe collars, pipe reducers,
compression couplings etc.).
- Before the installation, casing or insulating material
on the pipe must be removed. Thin coats of paint can
be left.
- Fe: The iron and metal concentration in the water
should not exceed 1 mg/l (1 ppm)
- Mn: The manganese level should not exceed 0.1 mg/l
(0.1 ppm)
- Boilers and heaters: calmat® works best for systems
with heating elements surface temperatures of max.
203°F/95°C.
Installation

Publicidad