VDS INV Istrucciones De Uso página 24

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SETTINGS and PROGRAMMING
Verify the direction of rotation of motor
After connecting, unlock the motor , place the door outside the
closing limit switch,
re-lock the engine and give power to the electrical panel.
Use buttons on board having the following features:
P1 key CLOSE
P2 key OPEN
P3 key CONFIRM / SELECT PROGRAMMING PHASE
Check that pressing the P1 the door closes and bring it up
to the closed position, verify that LD11 goes off.
Otherwise reverse ONLY 2 of the 3 motor phases.
Check that on the display DS1 appears the
message
Check that the LED LD11 related to FCC is off
Function 01 - Select type of automation motor
Ÿ
three-phase 230Vac
(Sliding Door / Sectional / Gate).
= PS
(Fridge Door).
= PF
(Folding Door).
= PL
PROCEDURE:
Press P3 until the display shows
Press again P3 and release.
The display shows
(NOTE: The sub-menu selection is distinguished from the point after the digit).
If you need to select another type of automation, act on the P2 button to display the
number corresponding to the type of automation desired.
Confirm pressing P3 (at this point will disappear the dots to the left of the digits).
After programming follow the procedure for ESC:
Press P2 (Forward) or P1 (Backward) l you see
Confirm pressing P3.
= DOOR CLOSED
= sliding gate.
and release.
P1
P2
P3
DS 1
88

Publicidad

Tabla de contenido
loading

Productos relacionados para VDS INV

Tabla de contenido