Installing 4-Wire Power Cord

WARNING
To avoid the risk of severe electrical shock or death,
ground wire must be attached to frame of range,
using ground screw provided. Ground wire must not
contact any other terminal.
POWER LEAD
connect wire with black or
red insulation and brass
terminal
POWER TERMINALS
(240 OR 208 VOLTS
BOTH SIDES)
1. Remove rear wire cover.
2. Place strain relief (winged clamp) in cord access hole
below terminal block.
• Place wings through hole entering from bottom.
• Screw holes in clamp should be below mounting
panel.
3. Remove grounding strap attached to center terminal
on terminal block.
• Strap is not needed for this installation.
• Remove green ground screw and retain for use in
step 7.
4. Place cord through strain relief.
• Attach cord neutral (center) or white wire to center
terminal on terminal block.
5. Attach power lead, red wire or black wire to left
terminal.
6. Attach power lead, red wire or black wire to right
terminal.
7. Attach green or bare wire to back of range using
green ground screw previously removed in step 3.
8. Attach wires using hex nuts provided.
• Firmly tighten to insure proper electrical
connection.
9. Place screw through strain relief, tighten, and replace
rear wire cover.
NEUTRAL TERMINAL
connect wire with white
insulation
POWER LINE
connect wire with black or
red insulation and brass
terminal

Converting 3-Wire to 4-Wire Power Cord

1. Remove rear wire cover.
2. Remove bottom strain relief screw and retain for
further use.
3. Remove screw/hex nuts from terminal block and
retain for further use.
4. Remove all 3-wire or cable leads from the terminal
block and proceed to remove the power cord from the
unit by pulling in a downward motion so that cord is
removed from strain relief.
5. Remove the grounding strap attached to the center
terminal on the terminal block.
• Grounding strap is not needed for this installation.
• Remove green ground screw and retain for future
use.
6. To install the 4-wire cord, please follow step 4 through
step 9 of Installing 4-Wire Power Cord section.
7. Reinstall rear cover and secure it with screw
removed earlier.

Level Range

CAUTION
To avoid damaging oven door, do not lift or move range
by oven door handle. Glass can break.
Carefully level range using legs provided. Range must be
level to cook and bake uniformly.
• Place a level on top oven rack or on top of range
when leveling.
• Leveling legs must be extended out ¼ inch to
engage anti-tip bracket.

Removal and Replacement of Range

1. Disconnect power to range.
2. Slide range forward.
3. Unplug range cord and place range aside.
4. Remove anti-tip bracket.
5. Install anti-tip bracket into new location using
instructions provided with bracket or see Anti-tip
Bracket Installation section in this manual.
6. To reinstall range, follow instructions in Installation
section of this manual.