Unit description

2.4. Protection

This charging station has several protections, as described below.
A.
Q4 (AC). 80 A Curve C thermal magnetic
circuit breaker (only Trio)
B.
RD3 (AC). 30 mA 63 A Type B residual
current circuit breaker (only Trio)
C.
QAC (DC). 100 A Curve C thermal magnetic
circuit breaker

2.5. Accessories equipped as standard

Ethernet communication.
Local communication with other INGEREV stations.
Compatible with OCPP.
Authentication via RFID / NFC cards.
Interface via display.
Steel enclosure highly resistant against adverse weather conditions.
ABT2012IQM01_ - Installation and Operation Manual
C
D
A
B
F
E
D.
RD1 (DC). 30 mA 100 A Type A residual
current circuit breaker
E.
Q2 (auxiliaries). 6 A Curve C thermal magnetic
circuit breaker
F.
RD2 (auxiliaries). 30 mA 25 A Type AC
residual current circuit breaker