Ferroli SUN M 50 Instrucciones De Uso, Instalación Y Mantenimiento página 44

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Burner setting
For a preliminary burner adjustment, set the head, air shutter and gas valve at the time of installation
(before commissioning and subsequent setting with instruments) using the following tables.
SUN M50 setting
Model
GN4 N 10
GN4 N 11
GN4 N 12
GN4 N 13
RSW 350
RSW 399
RSW 469
RSW 525
SUN M70 setting
Model
GN4 N 14
RSW 600
44
P. Firebox
P. Firebox
max.
min.
position
kW
kW
388
229
452
266
516
309
600
352
378
242.5
432
277.5
507
325
567.5
364.5
P. Firebox
P. Firebox
max.
min.
position
kW
kW
695
416
648
417
Cod. 35447686 - 04/2008 (Rev. 00)
SUN M50 - M70
Gas valve
1" 1/4
Head
1" 1/2
2"
G20
G31
mark
N
V
N
1
0.48
1.05
0
1.5
0.4
1.05
0
1.8
0.2
1.1
0
2.5
0.4
1.15
0
1.5
0.4
1.05
0
2
0
1.05
0
3
0.4
1.20
0
3
0
1.25
0
Gas valve
1" 1/4
Head
1" 1/2
2"
G20
G31
mark
N
V
N
1
0
1
0
1
0
1
0
Gas valve
Servomotor
3/4"
G31
1st st
V
N
V
Orange
0.85
0
1.05
10
0.85
0
1.15
10
0.9
0
1.2
20
0.95
0
1.10
20
0.85
0
1.05
8
0.85
0
1.15
10
0.90
0
1.20
13
0.90
0
1.20
20
Gas valve
Servomotor
3/4"
G31
1st st
V
N
V
Orange
0.8
0
1
10
0.8
0
1
10
cam
2nd st
Red
70
70
70
70
30
35
43
70
cam
2nd st
Red
70
50
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sun m 70

Tabla de contenido