,cE, WATE.66
Trouble
TOPIC
POSSIBLE
CAUSE
SOLUTION
Shooting
Ice maker is not producing
ice (some models-continued)
Improper water valve was installed.
Check
water connection
procedure
in your Installation
Instructions.
Self-piercing
and 3/16" saddle
valves cause low
water
pressure
and may clog the line over time. Amana
is not
responsible
for property
damage
due to improper
installation
or water
connection.
Unit is leaking water
Plastic tubing was used to complete water
Amana recommends
using copper tubing for installation.
connection.
Plastic is less durable and can cause leakage. Amana is
not responsible
for property damage
due to improper
installation
or water connection.
Improper water valve was installed.
Check water connection procedure
in your Installation
3
Instructions. Self-piercing
and 716"saddle valves cause low
water pressure and may clog the line over time. Amana is
not responsible
for property damage
due to improper
installation
or water connection.
Ice forms
in inlet tube to ice
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
maker
square inch to function properly. A minimum pressure of 35
pounds per square inch is recommended
for units with
water filters.
Freezer temperature
is too high.
See the controls section in your owner's manual for
assistance on how to adjust your controls. Freezer is
recommended
to be between 0 to 2°F (-18 to -17°C).
Water flow is slower than
Water pressure is low.
Water pressure must be between 20 to 100 pounds per
normal
square inch to function properly. A minimum pressure of 35
pounds per square inch is recommended
for units with
water filters.
Improper water valve was installed.
Check water connection procedure
in your Installation
Instructions. Self-piercing
and 3/16"saddle valves cause low
water pressure and and may clog the line over time.
Amana is not responsible for property damage due to
improper installation or water connection.
Copper or plastic tubing has kinks.
Turn off water supply and remove kinks.
If kinks cannot be
removed, replace tubing.
Change water filter.
Dispenser water is not cold
Allow approximately
12 hours for water in holding tank to
chill.
Water filter is clogged or needs to be
changed.
Refrigerator
has been recently installed
Water supply in holding tank has been
depleted.
Water has settle into water lines outside
holding tank and has warmed to room
temperature.
Discard first glass of water and refill.
21