Before Diving; After Diving - AirScape MiniDive Pro Instrucciones De Empleo

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNINGS
• In case of floral or suspicion of dysfunction, do not place your ears near the equipment, close the valve and refer to
these instructions, contact your dealer if necessary

5.1 Before diving

• In addition to a good health, it is necessary for the user to consult a health specialist
• Visually control the equipment before opening the valve
• The MP and HP outputs of the first stage should not be easily slacked by hands when the pressure regulator is not
under pressure, idem for hose / 2
• During the opening of the valve, do not direct the manometer towards you
• To open the tank, slowly turn the cuff of the valve in the counterclockwise direction,
then make a quarter turn backwards (do not let the valve reaching the stop)
• Make 2 or 3 inspiration/expiration cycles test before setting to water to verify the good working
• Never do a rotation (except the ones provided by this purpose) of the element after the pressurizing
• Adapt your dive to the pressure on the manometer
WARNINGS
• If the valve is not completely open, the user will not be able to use all the compressed air of the tank so it is therefore
essential to entirely open the valve and then, a quarter turn backwards
5.2 When diving
• Always adopt flexible and continuous breathing
• Use the equipment in a water above +10°C (50°F)
• MiniDive Pro (Pro+, Carbon) should only be used by one person at a time
• The maximum depth authorized is 3 m (10 ft)
• Regularly control the remaining pressure of the tank with the manometer
• The user should stay at the surface when the remaining pressure is equal or inferior to 50 bar (725 PSI) (red
zone of the manometer)
• Stop the dive in case of leak coming from the MiniDive Pro (Pro+, Carbon), slowly go back up to the surface
• Plan to stop using the equipment before the total lack of compressed air
• For the users of the MiniDive Carbon with the Seabob, they should use for the Seabob F5, at most the third speed. For
the Seabob F5S and F5R, it's at most the fourth speed.
WARNINGS
• Never go back up to the surface faster than the air bubbles
• Stop the dive in case of discomfort towards the ears or sinuses, do not dive with a cold
• NEVER stop your respiration during your descent or your ascent
• Do not immerge the MiniDive Pro (Pro+, Carbon) when it is not pressurized

5.3 After diving

After using the MiniDive Pro (Pro+, Carbon), please follow the following instructions :
-
Remove the remaining water in the second stage
-
Close the valve
-
Purge the top compartment by pressing the membrane
-
Rinse out the equipment in pure water
-
Let the equipment dry
• Do not use aerosols or other solvents for the cleaning
WARNINGS
• The cleaning of the second stage has to be gently done. A too strong jet of water through the mouthpiece can damage
the internal membrane
nd
stage regulator connexion
6
valve must be completely open,

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Minidive pro+Minidive carbon

Tabla de contenido