GENERAL SAFETY

If correctly installed and used, this automation device satisfies the required safety level standards. However, it is advisable to observe
some practical rules in order to avoid accidental problems.
Before using the automation device, carefully read the operation instructions and keep them for future reference.
Keep children, people and things outside the automation working area, particularly during its operation.
Keep radio control or other control devices out of children's reach, in order to avoid any unintentional automation activation.
Do not intentionally oppose the leaf movement.
Do not modify the automation components.
In case of malfunction, disconnect the power supply, activate the emergency release to have access to the automation and request the
assistance of a qualified technician (installer).
Before proceeding to any outside cleaning operation, disconnect the power supply.
Keep the photocell optical components and light signal devices clean.
Check that the safety devices (photocells) are not obscured by branches or shrubs.
For any direct assistance to the automation system, request the help of a qualified technician (installer).
Have qualified personnel check the automation system once a year.
Manual release activation could cause the door to be subject to uncontrolled movements in the case where any mechanical faults are
present or the door is not balanced.
Inspect the installation frequently if it shows any unbalance or signs of mechanical damage to "cables and supports". Do not use the
operator if it needs to be repaired. Keep the instructions together with the technical brochure for future reference.
This product was exclusively designed and manufactured for the use specified in the present documentation. Any other use not
specified in this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting from improper use of the product, or use which is different
from that expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following European Directives: 2004/108/EEC, 2006/95/EEC,
98/37/EEC and subsequent amendments. As for all non-EEC countries, the above-mentioned standards as well as the current national
standards should be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when
constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.
The installation must comply with the provisions set out by the following European Directives: 2004/108/CEE, 2006/95/EEC, 98/37/EEC
and subsequent amendments.
Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magneto thermal switch on the mains power supply, having a contact opening distance equal to or greater than
3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for closure (doors, gates etc.) and all system components provided
with an earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing,
conveying and shearing.
Position at least one luminous signal indication device (blinker) where it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety and correct operation when other manufacturers'
components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorized by the company.
Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualified
personnel.
Check that the stated temperature range is compatible with the place where the operator is to be installed.
If present, the dead man push button must be fitted within sight of the door but away from the moving parts, at a height of 1.5 m, and
must not be accessible to the public.
If the operator is fitted at a height lower than 2.5 m, you must guarantee an adequate degree of protection for the electrical and
mechanical parts.
Make sure that squashing is avoided between the moving parts and surrounding fixed parts. Fit all the safety devices (photocells,
safety edges etc.) required to protect the area from any danger of squashing, drawing in and shearing.
After completing the installation, ensure that the motor is set correctly and that the protection and release systems operate correctly.
Anything which is not expressly provided for in the present instructions is not allowed.