Arco 25/35
Fig.3
Prepare the electrical system as shown in Figure 3 with reference to existing standards for electrical installations.
Keep connections entirely independent of the operator (photocells, safety edges, control devices, etc.). Make all connections and
safety devices in accordance with the standards for the installation as mentioned above.
The main automation components are
Control panel and integrated receiver
Key selector
Flashing Lamp
ARCO Operator
Warning! All metal parts of equipment and automation must be grounded. For actuator wiring and accessory connection, refer to the
relevant instruction manuals. The control panels and accessories must be suitable for use and conform to current standards.
Should the opening or closing direction be incorrect, it is possible to invert the connections of operation A and operation B (brown/black)
on the control board.
The first command after the power supply cut should be an opening maneuver.
6. ADJUSTING THE PUSHING FORCE
WARNING: Check that the impact force value measured at the points established by the EN 12445 standard is lower than
that specified in the EN 12453 standard
The pushing force is calibrated by means of the torque regulator in the control unit. The optimum torque must allow a complete
opening or closing cycle with the minimum force necessary. An excessive torque can reduce the anti-crush safety. In the other
case, an insufficient torque can impede the maneuvers. Consult the control unit's instruction manual.
7. CHECKING THE AUTOMATION
Before considering the automation completely operational, the following checkings must be made with great care:
• Check that all the components are firmly anchored.
• Check all the safeties work properly (i.e. photocells, safety edges, etc.).
• Check the emergency maneuver control.
• Check the opening and closing maneuvers using the controls.
• Check the control unit's electronic logic in normal (or customized) operation.
8. USE OF THE AUTOMATION
Since the automation may be remote controlled either by radio or a Start button, it is essential that all safeties are checked
frequently.
Any malfunction should be corrected immediately by a qualified specialist.
Keep children at a safe distance from the field of action of the automation.
9. THE CONTROLS
The use of automation allows motorized opening and closing of the door. The controls can come in various forms (i.e. manual,
remote controlled, limited access by magnetic badge, etc.) depending on needs and installation characteristics. For details on the
various command systems, consult the specific instruction booklets.
Anyone using the automation must be instructed in its operation and controls.
10.
MAINTENANCE
When carrying out maintenance operation on the controller, disconnect it from the mains power supply. The actuator does not
require periodical maintenance operations.
• Check the safety devices of the gate and automation.
• Periodically check the pushing force and correct the value of the electric torque in the control board if necessary.
• In case of unsolved operation failures, disconnect the unit from the mains power supply and ask for the intervention of qualified
personnel (installer).
When the unit is out of order, activate the manual release to perform manual opening and closing maneuvers.
(fig.3):
Pair of outside photocells
Pair of inside photocells
4-6 channel VARIO transmitters
Antenna
19