2- WARNINGS

Carefully read the following information in order to
properly handle the air conditioner. Several types
of safety warnings and advice are listed below:
These units should be installed and used in
accordance with the Regulations and Standards
for
refrigerator,
electrical
equipment prevailing in relation to the location of
such installations.
As part of its policy for ongoing improvements of
its products, Saunier Duval reserves the right to
modify these specifi cations without prior notice.
Saunier Duval cannot foresee all the possible
circumstances that could pose a potential risk.
These units have been designed and manufactured
for the purposes of acclimatisation by means of air
conditioning; the use thereof for other domestic
or industrial purposes shall be the exclusive
responsibility of the persons projecting, installing
or using them in that way.
Prior to the performing any work on the unit, its
installation, commissioning, use or maintenance,
the personnel in charge of these operations
must be familiar with all the instructions and
recommendations
contained
installation manual.
In the event that any irregularity is detected (e.g.
smell of smoke), unplug the unit from the power
supply immediately and contact the distributor in
order to proceed appropriately.
If the air conditioner continues to be used in these
irregular conditions, it could be damaged and
cause a short circuit or a fi re.
Do not insert fi ngers or other objects in the air
inlets and outlets or in the slats whilst the air
conditioner is in operation since the high speed of
the fan could cause injury.
Call the technical specialist in order to take the
appropriate preventative measures in the event
of a refrigerant gas leak. Refrigerant leakages in
certain quantities can cause loss of oxygen. If the air
conditioner is installed in a small room, ensure that the
necessary measures are taken to prevent any symptoms
of lack of oxygen in the event of a refrigerant leak.
In the event that the air conditioner is removed and
subsequently reinstalled, its proper installation
must be adequately verifi ed. Otherwise, water or
refrigerant leakage could occur, as well as short-
circuiting or even fi re.
and
mechanical
Do not dismantle the outdoor unit's air vent.
Exposing the fan is very dangerous.
It is convenient to regularly check the base of the
outdoor unit to detect possible wear and tear. If a
damaged base is not repaired, it could come away
and cause an accident.
Do not place any items on top of the outdoor unit.
Do not handle the unit with wet or damp hands as
this would cause a risk of electrocution.
Only use the right fuses for each model. Do not
use wire or any other material to substitute the
fuse. This could cause faults or fi re.
Do not place any heat source with a fl ame in the
airfl ow of the unit. Do not use sprays or other
infl ammable gases close to the air conditioner
since this could cause a fi re.
in
the
unit's
Air conditioner must not be installed close to a
heat source, fl ammable or corrosive materials or
near an air vent of a neighbouring building.
Disconnect the power source when cleaning the unit.
This will avoid the risk of short-circuiting or injury.
Do not use water to clean the unit.
Connect the earth wire to the right line (never to the
gas pipes, water pipes, neutral line or telephone
line). Direct earthing can cause electrical risk.
Connect the condensed water pipe correctly to
ensure effi cient drainage. Incorrectly connecting
the pipe could cause a water leakage.
all differentials in order to prevent short-
circuiting.
Do not connect the equipment whilst insecticides
or pesticides are in use. Toxic chemicals could be
deposited in the air conditioner and affect persons
with allergies to the chemical substances.