Electrical

Power Cord

WARNING: Install the power cord
so that it is stored or secured to avoid
tripping or snagging and to reduce the
risk of fire, electric shock, or injury to
persons.
WARNING: This fireplace is
for use on a 120V circuit and has a
grounding plug that looks like the plug
in Figure 1. Make sure the plug is
connected to an outlet having the same
configuration as the plug. No adapter
should be used with this product.
Figure 1
WARNING: Do not use this
fireplace with an extension cord. Plug
the cord directly into an ap propriate
wall receptacle.
Removing Power Cord for
Hardwire Installation
To remove the power cord:
1.
Locate the power cord on the back
of the fireplace. Remove 2 screws
and slide the electrical box back.
2.
Unscrew the 2 wire connectors.
3.
Cut the green (ground wire) leaving
enough length to reuse the wire.
4.
Replace assembly with the hardwire
cover (included).
11