09/12 class
[Method of mounting conduit]
• A protection plate is fi xed for protection from the high-voltage section.
1) Dismount the stop valve cover by removing the screw.
2) Dismount the protection plate by removing the 2 screws.
3) Dismount the conduit mounting cover by removing the 2 screws.
4) Pass wires through the conduit and secure them with a lock nut.
5) After completing the work, reattach the stop valve cover, the conduit mounting cover, and the protection plate to its original position.
SIG
SIG
Shape wires so that
the proctection plate
and conduit mounting
plate fi t securely.
Conduit
mounting
plate
Lock nut
Conduit
18/24 class
[Method of mounting conduit]
1) Dismount the service lid by removing the screws.
2) Pass wires through the conduit and secure them with a lock nut.
3) After completing the work, reattach the service lid to its original position.
Power supply
terminal block
SIG
Shape wires so
that the proctection
plate and conduit
mounting plate fi t
securely.
Lock nut
Conduit
Conduit mounting plate
ELECTRICAL WIRING CONNECTION
Power supply
terminal block
SIG
SIG
SIG
1-15
Protection plate
Screws
Conduit
mounting
cover
Screws
Service lid
Screws
Screws