Description
LED II will shine if the supply battery (battery II) is charged, if
there is mains voltage and if battery II is connected.
If the voltage on battery II is 14.1 V, the starter battery (battery I)
is also switched (in parallel) and charged. LED I shines.
If the mains supply mode fails, the batteries initially remain
switched in parallel, LED I continues to shine, LED II goes off.
If the voltage of the batteries falls below 13.2 V, the batteries
are automatically disconnected by the charger. LED I goes off.
In driving mode, the supply battery (battery II) and the starter
battery (battery I) are automatically connected to each other
via the charger. LED I shines.
Malfunctions of the charger BC 616 IU are indicated when the
LED II flashes.
Panel BC (616)
Panel BC (616)
LED I
LED II
6
Made in Germany
Made in Germany
Maintenance
Clean the device with a dry and fluff-free cloth.
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective land in which it is used.
National regulations and laws (in Germany, for example,
the Altfahrzeug-Verordnung [old vehicle directive]) must be
observed.

Technical Data

Front plate
Aluminum
Ambient temperature
-25 °C to +50 °C
Width
54 mm
Height
45 mm
Depth
25 mm
Weight
15 g
The right to effect technical modifications is reserved!