Congratulations on your new radiator from LVI!
Alata
Radiator for wall mounting,. Electronic thermostat. Delivered with
4-wire cable and junction box, plus wall brackets and screws.
The electrical installation must be done by an authorised
electrician.
Rated voltage 230V alt. 400V.
If the supplied connection box is used, installation is classified
as IP32. If the installation is to be IP44, you can buy the KDNIP
splashing water protection accessory separately.
Alata P
Radiator for wall mounting, or for freestanding positioning.
Electronic thermostat. Supplied with connecting cable provided
with earthed plug, wall brackets and screws.
Rated voltage 230V.
IP 44.
InstallatIon
MountIng
Fig. 1
For the correct installation of radiators it is essential that the fixing of the
radiator is carried out in such a way that it is suitable for intended use AND
predictable misuse. A number of elements need to be taken into consideration
including the fixing method used to secure the radiator to the wall, the type and
condition of the wall itself, and any additional potential forces or weights, prior to
finalising installation.
The supplied wall brackets are mounted on wall with enclosed screws. The
brackets are ideally placed approx. 100-150 mm in from each end of the radiator.
The brackets can be used to mark out the height.
Fig. 2, 3
Note! The specified minimum measurements to floor, window sill and side wall
must be observed. The measurement in fig. 3 between floor and lower attach-
ment hole gives a distance of 100 mm between the floor and lower edge of the
radiator. It is important for the function of the radiator that it is mounted level.
The radiator is reversible. The thermostat housing should always be at the
bottom, closest to the floor. The radiator must not be placed immediately under a
wall socket or in the immediate nearness of a bath, shower or swimming pool.
Fig. 4
The wall upper end of the brackets can be pulled up and locked in their top posi-
tion to simplify the mounting of the radiator. Make sure when locking the radia-
tor in the brackets that the upper part of the brackets properly grip the edge of
the radiator.
Fig 5
Model Alata P can alternatively be provided with feet for freestanding positioning.
The feet are fitted by pressing them on the radiator as shown in the fig.
The radiator is reversible. The thermostat housing should always be at the
bottom, closest to the floor. The radiator must not be placed immediately under a
wall socket or in the immediate nearness of a bath, shower or swimming pool.
ConneCtIon of Model alata 230v alt. 400v
Fig. 6
The radiator's 4-wire cable is connected in the supplied terminal box, which is
ideally placed on the wall behind the radiator.
Make sure that the terminal box is not touching the back of the radiator.
The 4-wire cable is connected as follows:
Voltage:
230V
Brown wire: (1)
Phase
Blue or grey wire: (2)
Neutral wire
Black wire: (4)
Output controlled
phase. Used for "master/
slave" connection.
Green/yellow. wire: ( )
Earth
ConneCtIon of Model alata p
The radiator's connecting cable with earthed plug is connected to an existing wall
socket. For permanent connection via a wall terminal box, remove the plug from the
cable and connect to suitable wall terminal box. The terminal box is ideally placed on
the wall behind the radiator. Make sure that the terminal box does not touch the back
of the radiator. Suitable terminal boxes are E 14 376 00, E 14 377 00 etc.
The 3-wire cable is connected as follows:
Brown wire: (1)
Phase
Blue or grey wire: (2)
Neutral wire
Green/yellow. wire: ( )
Earth

how to use

Fig. 7
The radiator is switched on by setting the switch in position I, see fig. 7a. The
required room temperature is set with the thermostat dial, see fig. 7b. The
green lamp goes on when the radiator is emitting heat, see fig. 7c. If the set
temperature does not correspond to the achieved room temperature, the
thermostat can be adjusted. This is carried out by pulling the thermostat knob
(Illustration 7b) straight out and reinserting it so that the arrow points at the
measured room temperature.
If the red lamp is lit or flashes, see Illustration 7d, a fault has been detected by the
electronics. Contact your supplier.
Fig. 8
The radiator is provided with a lockable panel. It can be locked by moving the
catch as per fig. 8.
The radiator is fitted with electronic overheat protection which cuts the power
if the radiator gets too hot; if it is covered for example. This can be reset by
switching the radiator off and on. If the radiator cuts out repeatedly check that
no part of the radiator is covered. Otherwise contact your supplier. The radiator is
also fitted with overheat protection that cannot be reset, this trips if the radiator
overturns during stand-alone use. In some unfortunate circumstances this can
also trip when the radiator is covered. If it does trip the heating element must be
replaced, contact your supplier. If the radiator is removed from the wall brackets
even briefly, it has to be unconditionally turned off, see Fig 9.
MaIntenanCe
When cleaning or wiping, only use mild detergent.
MIsCellaneous
This radiator is filled with a precise amount of special oil, and therefore repairs
that need it to be opened must only be carried out by the manufacturer or their
service representative. In the event of leakage, contact your supplier or their
representative.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
400V
If the supply cord is damaged, it must be replaced by the manufacturer, its
Phase 1
service agent or similarly qualified persons in order to avoid a hazard.
Phase 2
Output controlled phase
When scrapping the heater, follow the regulations concerning the disposal of oil.
1. Used for "master/
slave" connection.
aCCessorIes
Grille and side plates, feet for model Alata P, and lock device for locking the upper
part of the radiator brackets are available as accessories. Contact your supplier for
Earth
further information.
warranty
The warranty is valid for 10 years except for electrical components which
is valid for 2 years. In the event of any problems or repairs, please contact your
supplier.
- 5 -
WARNING - In order to avoid overheating, do not cover the heater. "Do
not cover" means that the radiator must not be used for drying clothes
etc. by placing them directly on it.