ter, it is possible to carry out the machine descaling operation in order to eliminate the malfunction.
can be easily found in the Ariete technical assistance service centres. Ariete is not liable for dam-
age to internal components of the coffee machine caused by the use of non-compliant products
due to the presence of chemical additives. If a descaling is required, observe the directions on the
instruction sheet of the descaling product.
SETTING THE MACHINE OUT OF SERVICE
If it is required to set the machine out of service, disconnect it electrically, empty the water tank and
In case of scrapping it is necessary to provide for the separation of the various materials used in the
construction of the machine and dispose of them according to their composition and the provisions
of law in force in the country of use.
TROUBLESHOOTING
Warning!
If there are problems with operation, immediately turn off the machine
and unplug it from the socket-outlet.
tisanes.
steam.
-
22
Causes
Air has probably entered the
circuit and deactivated the
pump.
The steam exit hole on the
dispenser wand is clogged.
There is little water and the
pump does not suck.
The steam exit hole on the
dispenser wand is clogged.
coffee has been put into the
holder in its housing.
Ground coffee has remained
seat.
Make sure the tank is properly inserted
and that the water is not below the
minimum level. Repeat the operations
formed in the hole of the dispenser wand
with a pin.
Check that the water level in the tank is
water.
formed in the hole of the dispenser wand
with a pin.
slowly because any remaining pressure
-
could cause splashes or sprays. Clean
Repeat the operation placing the correct
Clean the seal with a toothpick or a