7.

Start-up

Before starting the blind rivet setting tool, read and observe the operating instructions and
safety information and keep in a safe place. Have technical personnel connect the compressed
air supply to the blind rivet setting tool.
7.1

Selecting and changing the nosepiece

Caution:
Always fit the nosepiece corresponding to the size of the blind rivet (refer to table in Section 6).
To change the nosepiece:
Disconnect the tool from the compressed air supply.
Unscrew nosepiece from steel head sleeve.
Screw in corresponding nosepiece and tighten.
7.2

To set a blind rivet

Connect the blind rivet setting tool to the compressed air supply.
Insert the blind rivet in the nosepiece and fit as far as it will go in the hole in the material
to be joined.
Press trigger until the mandrel breaks off.
Release the trigger.
The spent mandrel is conveyed into the spent mandrel container by tilting the tool back -
automatically in tools with spent mandrel evacuation - (see 8).