7.
Start-up
Before starting the blind rivet setting tool, read and observe the operating instructions and
safety information and keep in a safe place. Have technical personnel connect the compressed
air supply to the blind rivet setting tool.
7.1
Selecting and changing the nosepiece
Caution:
Always fit the nosepiece corresponding to the size of the blind rivet (refer to table in Section 6).
To change the nosepiece:
•
Disconnect the tool from the compressed air supply.
•
Unscrew nosepiece from steel head sleeve.
•
Screw in corresponding nosepiece and tighten.
7.2
To set a blind rivet
•
Connect the blind rivet setting tool to the compressed air supply.
•
Insert the blind rivet in the nosepiece and fit as far as it will go in the hole in the material
to be joined.
•
Press trigger until the mandrel breaks off.
•
Release the trigger.
•
The spent mandrel is conveyed into the spent mandrel container by tilting the tool back -
automatically in tools with spent mandrel evacuation - (see 8).
22