* available as optional accessory.
Extended version of nosepiece and other special versions are available on request.
Nosepieces for BULB-TITE
8.
Start-up
Before starting the blind rivet setting tool, read and observe the operating instructions and
safety information and keep in a safe place. Have technical personnel connect the com-
pressed air supply to the blind rivet setting tool.
8.1
To attach spent mandrel container
Fully screw on spent mandrel container (L) by turning clockwise.
8.2
Selecting and changing the nosepiece
Caution! Always fit the nosepiece corresponding to the size of the blind rivet (select from
table in Section 7).
To change the nosepiece
•
Disconnect the blind rivet setting tool from the compressed air supply.
•
Unscrew nosepiece (B) from steel head sleeve (C).
•
Screw in selected nosepiece (B) and tighten.
8.3
To set a blind rivet
•
Connect the blind rivet setting tool to the compressed air supply.
•
Insert the blind rivet in the nosepiece (B) and using the tool fit as far as it will go in the
hole in the material to be joined.
•
With the aid of the blind rivet setting tool, insert the blind rivet into the rivet hole.
•
Press the blind rivet setting tool against the material and overcome the preset triggering
force*.
•
Press the yellow trigger button (N) until the mandrel breaks off.
•
Release the yellow trigger button (N).
•
The spent mandrel is automatically conveyed into the spent mandrel container (L) (see
Section 8.5).
and MEGA GRIP
®
®
blind rivets available on request.
GB
21