WALMEC GENESI CARBONIO 360 HTE Clear Manual De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
Mod. GENESI CARBONIO 360 GEO
TECHNICAL SPECIFICATIONS
9 psi)
- Air fitting: G 1/4" M
- Maximum air pressure: 5 bar (73 psi)
UMPTION
ø
0.7
1.0
1.2
2.7 CFM)
1.3
1.4
1.5
1.7
1.9
** Product flow was calculated with water, setting the recommended regulations.
efficiency
At the recommended air pressure the spray gun respects the European and U.S. ecological norms for which the transfer efficiency
USE
her fluid
Spray guns in the GENESI CARBONIO 360 GEO series have been designed for the application of finishing colours in all those
sectors requiring high quality finishing and low fumes emission.
The instrument is not suitable for use with abrasives or products containing acids or petrol of any kind.
To obtain the best results, the following instructions must be followed carefully:
1. When possible, use an air hose with a minimum internal section of ø 10 mm (0,37").
2. Make sure water, oil or other impurities are fully filtered from the compressed air used (for example, by installing a
Walcom FSRD3/4 filter unit or the most complete and efficient Walcom TD3 PRO multifunction heat conditioner).
ADVICE FOR CORRECT USE
5,9").
1.The distance between the spray gun and the surface to be painted must be set between 100 and 150 mm (3.9"- 5.9").
ity.
If the spray gun is working at a too low pressure and at a too high distance, it will not perform to the best of its capacity.
2. The jet from the spray gun must always be perpendicular to the
surface being painted and the paint must be applied in horizontal
strokes. Any eventual shift from this position when spraying will
result in an uneven application of the paint layer.
3. Correct viscosity of the paint is between 15 and 25 sec. Ford
cup n°4. These values depend on the application and the nozzle
size used.
SHAPE OF THE FAN
ar jet
Adjust the air pressure, product quantity and spray
opening until obtaining a regular imprint as in fig. C
istruzioni WI34_18.indd 21
** PRODUCT LOAD (3.5 turns)
FEED
106 Gr/min. (3.7 oz/min.)
Gravity
168 Gr/min. (5.9 oz/min.)
Gravity
203 Gr/min. (7.1 oz/min.)
Gravity
222 Gr/min. (7.8 oz/min.)
Gravity
213 Gr/min. (7.5 oz/min.)
Gravity
248 Gr/min. (8.8 oz/min.)
Gravity
252 Gr/min. (8.9 oz/min.)
Gravity
255 Gr/min. (9.0 oz/min.)
Gravity
RECOMMENDED AIR PRESSURE DURING USE: 2 bar (29 psi)
must be above 65% and /or the air pressure at the exit of the air cap must not be superior to 0,7 bar (10 psi).
- Air pressure too low
- Product viscosity too high
- Quantity of product too high
ADJUSTMENTS
- Working pressure: 1,5-2 bar (22-29 psi)
- Fan: Fully open
- Product: 3,5-5 turns
FAN DIMENSIONS AT 15 cm (5.9")
17 cm (6.7")
19 cm (7.5")
21 cm (8.3")
22 cm (8.7")
23 cm (9.1")
24 cm (9.5")
25 cm (9.9")
26 cm (10.3")
- Air pressure too high
- Product viscosity too low
- Quantity of product too low
21
AIR CONSUMPTION
425 l/min (15 CFM)
- Regular jet
09/01/18 14.18