Repair Parts - Flotec FPSC1725X Manual Del Usuario

Bomba sumergible de uso general
Ocultar thumbs Ver también para FPSC1725X:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting • Repair Parts
Symptom
Pump won't start or run.
Pump starts and stops.
Pump operates but delivers little
or no water.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832.
Probable Cause(s)
Pump is not plugged in.
Blown fuse or breaker.
Low line voltage.
Defective motor.
Motor is overheating.
Restricted discharge (obstacle or ice in piping).
Restricted intake.
Low line voltage.
Worn or plugged impeller.
Anti-airlock hole is plugged.
1
2
3
4
Corrective Action
Check and see if pump is plugged in to a proper outlet.
If blown, replace with fuse of proper size or reset breaker.
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Replace pump.
Discharge or intake are obstructed. Pump is in too shallow of water.
Remove pump and clean pump and piping.
Remove the pump and clean out the intake screen.
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Replace pump.
Turn off the pump, clean out the anti-airlock hole, and restart the pump.

Repair Parts

Ref
Description
1
Power Cord
2
Adapter
3
Motor Assembly
4
Inlet Screen
** If the motor fails, replace the entire pump.
5
Qty .
Part Number
1
PS117-54-TSU
1
HA5
1
**
1
PS8-129P

Publicidad

Tabla de contenido
loading