Electrical Connections - Waeco MagicSafe MS620 Instrucciones De Montaje Y D’uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 117
MS-620.book Seite 55 Dienstag, 18. Oktober 2005 3:04 15
MagicSafe MS620
7

Electrical connections

The complete circuit diagram for the alarm system can be found in Fig. 8, page 7.
No. in
Description
Fig. 8, page 7
1
Control unit
2
Shock sensor
3
Status LED
4
Drive-off block (optional)
5
Convenience output
6
Bonnet contact switch
7
Boot contact switch
8
Door contact switch
9
Indicator switch
10
Indicator
11
Alarm siren
All plugs are coded so that you cannot connect them incorrectly.
7.1
Laying cables
When laying electric connections, ensure that
They are not kinked or twisted
They do not rub on edges
They are not laid in sharp edged ducts without protection (see Fig. 2, page 3).
Caution!
Before making any drill holes, ensure that no electrical cables or other parts of
the vehicle can be damaged by drilling, sawing and filing (see Fig. 1, page 3).
➤When laying cables in the engine compartment or boot, use existing open-
ings with rubber seals wherever possible.
Where there is no suitable opening, drill a hole with a diameter of approximately
13 mm, and insert a cable duct sleeve.
Note
Pull the socket connector of the cables through the cable sleeve, before insert-
ing the sleeve in the bodywork.
Lay out the cables in the motor or boot so that they cannot be damaged under any
circumstance (e. g. by flying grit).
Insulate all unused cable ends.
7.2
Connecting the P1 main cable tree (see Fig. 6, page 6)
Plug the P1 cable tree into the corresponding connection on the control unit.
Electrical connections