MS-620.book Seite 57 Dienstag, 18. Oktober 2005 3:04 15
MagicSafe MS620
If no original circuit diagrams are available, you will need to determine the function
of the control cables which run from the control device of the central locking to the
vehicle doors.
Caution!
Only connect MagicSafe via the control cables of the central locking and not
using other cables.
Connecting to other cables than the control cables or using an incorrect circuit
plan can lead to defects in the central locking and the remote control.
➤
Determine the control time of the central locking.
In some vehicles for example Mercedes, it may be the case that a control time of
0.5 s is not sufficient to completely activate the central locking. In such cases you
need to set the control time with software function 4 (see "Software functions" chap-
ter on page 75) to 4 s.
➤
Connect MagicSafe in accordance with the appropriate circuit diagram:
Vehicles without a servo motor in the driver's door (driver's door cannot be locked
and unlocked from the passenger's door) or with pressure vacuum central locking
without electrical control cables: see Fig. 10, page 8
In these cases you require an additional servo motor, WAECO type no. ML-11 for
the driver's door.
Two cables from negative to +12 V: Fig. 11, page 9
Two +12 V pulse control cables: Fig. 12, page 9
Two negative pulse control cables: Fig. 13, page 10
One open and negative pulse control cable: Fig. 14, page 10
One +12 V and negative pulse control cable: Fig. 15, page 11
For the connection to the WAECO central locking ML-44(22) IR: Fig. 16, page 11
Connection to the WAECO central locking ML-44(22): Fig. 17, page 12
➤
Insulate any unconnected cables.
No. in
fig. 11 to fig. 15
1
Description
Control device of the vehicle's own central locking
Electrical connections
57