Lenze L-force Controls EL 1800 Instrucciones Para El Montaje página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

2
Safety instructions
Safety instructions for the installation according to UL
Ratings
Input 24 V DC, 65 W
ƒ
Max. Ambient Temperature 40 °C
ƒ
EL6xx, EL1xxx, EL5xxx, EL9xxx only
Max. Surrounding Temperature 50 °C
ƒ
EL8xx, EL2xxx, EL7xxx only
Optional communication ratings:
ƒ
RS232−Connection: max. 3 A
USB−Connection: max. 1 A
PS/2−Connection: max. 1 A
LAN−Connection: Standard ISDN or RJ45
Environmental ratings: If these devices are mounted into a door or front
ƒ
cover of an enclosure: Type 1 enclosure.
J
Warnings!
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ
ƒ
ƒ
Power supply
ƒ
ƒ
Battery
ƒ
ƒ
ƒ
24
Use Copper Wire only.
AWG 18 ... AWG 12 (0.82 mm
Torque 5...7 lb−in (0.5 ... 0.6 Nm)
Must be used as isolating source.
Rated data: 24 VDC, 4 A max.
Replace Battery with any from the list below, Part No. CR 2450
only. Use of another battery may present a risk of fire or
explosion.
Recommended CR2450 (R/C, BBVC2) types:
Renata Part.no. CR2450N, Sony Corp. part no. CR2450B, Toshiba
part no. CR2450, Varta part no. CR2450, Matsushita part no.
CR2450
Battery may explode if mistreated. Do not recharge, disassemble,
dispose of in fire or heat above 100 °C (212 °F).
Dispose of used battery according to the regulation of recycling
or waste.
2
2
... 3.3 mm
)
l
MA_ELx8xx DE/EN/FR/ES/IT 2.0

Publicidad

Tabla de contenido
loading

Tabla de contenido