ENGLISH
6. MAINS INPUT: with IEC socket; connect the supplied mains cable here.
7. DMX OUTPUT: 3pin XLR connector (pin1 = ground/shield ; pin2 = data- ; pin3 = data+)
8. DMX INPUT: 3-pin XLR connector (pin1 = ground/shield ; pin2 = data- ; pin3 = data+)
CONNECTIONS WR-DMXG4 RECEIVER
9. MAINS INPUT: with IEC socket; connect the supplied mains cable here.
10. DMX OUTPUTS: the WR-DMXG4 has 2 identical DMX-outputs: you can use the 3pin XLR connector
(pin1 = ground/shield ; pin2 = data- ; pin3 = data+) or the 5-pin XLR connector (pin1 = ground/shield ;
pin2 = data- ; pin3 = data+ ; pins 4/5 = not used). Don't use both together !
OVERHEAD RIGGING
You can use the M10 thread on the top of the box to fix a rigging hook.
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well-ventilated spot, far away from any flammable materials and/or liquids.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
BRITEQ
®
4/30
OPERATION MANUAL
WIRELESS DMX SYSTEM