Service DC AirCube 1200, 2000
While performing cleaning or maintenance on the
machine, the unit should be off and disconnected
from the power supply.
When the suction is reduced, due to the fi lters be-
coming clogged, the red light will come on. (Note:
This feature is only at max speed.)
This feature is only at max speed.)
The pre-fi lter should be changed. If the light is still
on the the HEPA fi lter should be changed too.
With heavy dust loads the life of the fi lters are
shorter. Use only original spare part fi lter. Use sui-
table breathing protection and do the operation in
a closed room. The used fi lter should be sealed in
a plastic bag and disposed of according to appro-
ved methods.
Check regularly that the electrical cable is not da-
maged in any way. With replacement of the cable
and contact, use only water proof replacements.
Change the fi lter:
DC AirCube 1200
The DC AirCube 1200, 2000 should be perfor-
mance tested and checked at least once per year
or more frequently if subject to intensive use.
Because this machine is used with dangerous sub-
(Note:
stances maintenance is vital, worn parts should be
replaced.
Never compromise the function of the DC AirCube
1200, use only original spare parts.
The fan is maintenance free.
DC AirCube 2000
DC AirCube - 17
Part No 94178-C