SAMES KREMLIN SLR S-BOX Manual De Explotación página 43

Tabla de contenido

Publicidad

Measured resistance has
33
rS
exceeded the parameter
range
Keypad has been removed
when the drive is receiving
34
Pad
the reference from the key-
pad
Trip initiated from the Control
35
CL.bt
Word (06.042)
User Save error / not com-
36
U.S
pleted
37
Pd.S
Power down save error
38-39
rES
Spare
Communication has been
lost / errors detected
90
LF.Er
between power, control and
rectifier modules
User 24 V supply is not present
91
US.24
on the adaptor interface ter-
minals (1,2)
Snubber over-current detec-
92
OI.Sn
ted
Communication has been
93
Pb.Er
lost / errors detected
between power control
94-96
rES
Spare
Drive parameters are being
97
d.Ch
changed
98
Out.P
Output phase loss detected
99
rES
Spare
100
rESEt
Reset drive
Braking IGBT over-tempera-
101
Oh.br
ture
Indice de revisión : E - Julio de 2017
• Check the motor cable / connections
• Check the integrity of the motor stator winding
• Check the motor phase to phase resistance at
the drive and motor terminals
• Ensure the stator resistance of the motor falls
within the range of the drive model
• Perform a user save in Pr mm.000 to ensure that
the trip doesn't occur the next time the drive is
powered up.
• Ensure that the drive has enough time to com-
plete the save before removing the power to the
drive.
• Perform a 1001 save in Pr mm.000 to ensure that
the trip doesn't occur the next time the drive is
powered up.
• Hardware fault - contact the supplier of the drive.
• Ensure the user 24 V supply is present on the user
terminals on the adaptor interface.
• Ensure the internal EMC filter is installed
• Ensure the motor cable length does not exceed
the maximum for selected switching frequency
• Check for supply voltage imbalance
• Check for supply disturbance such as notching
from a DC drive
• Check the motor and motor cable insulation with
a Megger
• Install a output line reactor or sinusoidal filter
• Hardware fault – Contact the supplier of the drive
• Ensure the drive is not enabled when defaults are
being loaded
• Check motor and drive connections
• Check braking resistor value is greater than or
equal to the minimum resistance value
43