SAMES KREMLIN SLR S-BOX Manual De Explotación página 46

Tabla de contenido

Publicidad

Soft start relay failed to close,
226
So.St
soft start monitor failed
227
r.ALL
RAM allocation error
228
OI.SC
Output phase short-circuit
229-
rES
Spare
230
231
Cur.c
Current calibration range
232
dr.CF
Drive configuration
233-
rES
Spare
234
235
Pb.HF
Power board HF
236
No.PS
No power board
237
FI.In
Firmware Incompatibility
238-
rES
Spare
244
Power board is in bootloader
245
Pb.bt
mode
246
dEr.e
Derivative file error
247
Fi .ch
File changed
Derivative product image
248
dEr.I
error
249
rES
Spare
250
r.b.ht
Hot rectifier/brake
251-
rES
Spare
254
255
rSt.L
Indice de revisión : E - Julio de 2017
Hardware fault – Contact the supplier of the drive
Over-current detected on drive output when
enabled. Possible motor earth fault.
• Check for short circuit on the output cabling
• Check integrity of the motor insulation using an
insulation tester
• Is the motor cable length within limits for the
frame size?
Current calibration range error.
The hardware ID does not match the user software
ID.
• Hardware fault - Contact the supplier of the drive
No communication between the power and
control boards.
• Check connection between power and control
board.
The user firmware is incompatible with the power
firmware.
Re-program the drive with the latest version of the
drive firmware for Unidrive M200.
Power cycle the drive
Contact the supplier of the drive
Over-temperature detected on input rectifier or
braking IGBT.
46
6424

Publicidad