Vacation
• When leaving on vacation, turn off the humidifier water supply and your humidistat.
• When you return, turn on the humidifier water supply and reset your humidistat.
CHECKING YOUR HUMIDIFIER FOR
CORRECT OPERATION
After winter startup or servicing, use the following steps to check your humidifier
operation:
1. Turn on the humidifier power and water supply.
2. Turn the humidistat to its highest setting and set the thermostat to 10°F (6°C)
above the room temperature.
3. Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be running to activate the humidifier.
4. Reset the thermostat and humidistat to a comfortable setting for automatic oper-
ation.

TROUBLESHOOTING YOUR HUMIDIFIER

Problem
Water leakage
HE220, HE260 HUMIDIFIER AND INSTALLATION KIT
Table 3. Troubleshooting Humidifier.
What to look for
Leaking joints.
Brass tubing inserts
Saddle valve leaking.
Shut off water.
Tighten connections.
Verify that brass tubing inserts are
used.
Verify rubber pad is installed on saddle
valve.
17
What to do
69-2630ES—03