3
Technical Data
Safety Valve 451r / 851r
DN
Inlet / x outlet
Min. flow diameter in mm
Set pressure [bar]
Fluid / fluid group
Bursting disc TC(R)-(SGK)KUB
DN
TC(R)-(SGK)KUB
Nominal diameter DN
(clear width D2) in mm
Set pressure at 22°C [bar]
Permissible operating
temperature TS [°C]
Fluid / fluid group
4
Field of application / operating principle
Combinations of bursting discs and safety valves are used in a wide range of
applications in which the tightness of the system in ongoing operation is particularly
important.
Furthermore, once the bursting disc responds and the pressure has been reduced
to a level low enough for safe operation of the system, the system is sealed again
reliably by the safety valve.
The bursting disc protects the safety valve and ensures, for example, that it does
not develop leaks due to contamination and/or does not open prematurely.
Assembly and maintenance instructions - 451r / 851r
20
G¾" x G 1 1/4"
18
≥ 3,2 to 25,0
gases and vapours / 1 and 2
20
-0,75
26,9
≥ 3,2 to 25,0
gases and vapours / 1 und 2
25
G1" x 1 1/2"
23
≥ 3,0 to 25,0
25
-1
33,7
≥ 3,0 to 25,0
-40 °C to +200 °C
32
G 1 1/4" x G 2"
30,3
≥ 2,0 to 16,0
32
-1,25
42,4
≥ 2,0 to 16,0