Instructions for Use
Reusable RFP-100A
Connector Cable
Baylis Medical Company Inc.
5959 Trans-Canada Highway
Montreal, Quebec, Canada, H4T 1A1
Tel: (514) 488-9801/ (800) 850-9801 Fax: (514) 488-
7209
www.baylismedical.com
EU Authorized Representative:
Quality First International
20 Eversley Road, Bexhill-on-Sea, East Sussex
TN40 1HE, United Kingdom
Tel: +44-(20)-8-522-1937 Fax: +44-(20)-8-522-1937
© Copyright Baylis Medical Company Inc., 2009-2018
Baylis Medical logo is a trademark and/or registered trademark of Baylis
Medical Company Inc. In the United States of America and/or other
countries. All other trademarks or registered trademarks are property of
their respective owners.
English
Carefully read all instructions prior to use. Observe all contraindications, warnings
and precautions noted in these instructions. Failure to do so may result in patient
complications.
Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a
physician.
I.
DEVICE DESCRIPTION
The Reusable RFP-100A connector cable connects the Baylis Medical Company
RFP-100A Radiofrequency Puncture Generator (RFP-100A Generator) to Baylis
Medical approved radiofrequency puncture devices.
radiofrequency (RF) power to be delivered from the Generator to the puncture
device.
Detailed information concerning the RFP-100A Generator is contained in a
separate manual that accompanies the Generator (RFP-100A Generator
Instructions for Use). In addition, detailed information concerning the RF puncture
devices is contained in separate manuals that accompany these devices.
The dimensions for the Reusable RFP-100A connector cable can be found on the
device label and in section VII "Product Specifications." The Reusable RFP-100A
connector cable has a four-pin connector on one end that mates with the RFP-
100A Generator and a connector at the other end, which mates with the puncture
device.
II.
INDICATIONS FOR USE
The intended use of the Reusable RFP-100A connector cable is to connect the
RFP-100A Generator to Baylis Medical approved puncture devices (RF puncture
devices).
III.
CONTRAINDICATIONS
The Reusable RFP-100A connector cable is not recommended for use with any
other RF generator or any other device.
IV.
WARNINGS
The Reusable RFP-100A connector cable is a reusable device. Only use
the validated cleaning and sterilization methods as described in section XI
"Cleaning and Sterilization Instructions" to clean and sterilize the Connector
Cable.
No other cleaning and sterilization methods have been tested.
Failure to properly clean and sterilize the device can cause patient injury
and/or the communication of infectious disease(s) from one patient to
another.
The Reusable RFP-100A connector cable must only be used with the RFP-
100A Generator and RF puncture devices. Attempts to use it with other RF
Generators and devices can result in electrocution of the patient and/or
operator.
Laboratory staff and patients can undergo significant x-ray exposure during
radiofrequency puncture procedures due to the continuous usage of
fluoroscopic imaging. This exposure can result in acute radiation injury as
well as increased risk for somatic and genetic effects. Therefore, adequate
measures must be taken to minimize this exposure.
V.
PRECAUTIONS
Do not attempt to use the Reusable RFP-100A connector cable or ancillary
equipment before thoroughly reading the accompanying Instructions for Use.
Page 1 of 14
Baylis Medical Company relies on the physician to determine, assess and
communicate to each individual patient all foreseeable risks of the Baylis Medical
Radiofrequency Puncture System.
VI.
Adverse events associated with the use of this device are similar to those indicated
for the Baylis Medical Radiofrequency Puncture System.
VII.
Model Number
Strain Relief Colour
Overall Useable Length
Generator Connector
Device Connector
VIII.
Perform the following checks before the patient is presented for the procedure.
These tests will allow you to verify that the equipment you will use is in proper
working order. Do these tests in a sterile environment. Do not use defective
This Cable enables
equipment.
Visual Check
IX.
Puncture procedures should be performed in a specialized clinical setting which
may be equipped with a fluoroscopy unit, radiographic table, physiologic recorder,
emergency equipment and instrumentation for gaining vascular access.
X.
Once the RF puncture device is properly positioned at the puncture site, and the
Generator is properly set up (following the instructions in the RFP-100A Generator
Instructions for Use), the Reusable RFP-100A connector cable can be used to
connect the catheter or wire to the Generator.
1.
2.
3.
4.
5.
Puncture procedures should be performed only by physicians thoroughly
trained in the techniques of radiofrequency powered puncture in a fully
equipped catheterization laboratory.
The sterile packaging should be visually inspected prior to use to detect any
compromise. Ensure that the packaging has not been damaged. Do not use
the equipment if the packaging has been compromised.
Visually inspect the cable to ensure there is no cracking or damage to the
insulating material. Do not use the cable if there is any damage.
The Reusable RFP-100A connector cable is intended for use with RF
puncture devices only.
Never disconnect the Reusable RFP-100A connector cable from the RFP-
100A Generator while the Generator is delivering RF power.
Never disconnect the Reusable RFP-100A connector cable from the RFP-
100A Generator by pulling on the cable. Failure to disconnect the cable
properly may result in damage to the cable.
Do not twist the Reusable RFP-100A connector cable while inserting or
removing it from the Isolated Patient Connector on the Generator. Twisting
the cable may result in damage to the pin connectors.
Do not bend the cable. Excessive bending or kinking of the cable may
damage the integrity of the cable and may cause patient injury. Care must
be taken when handling the cable.
Take precautions to limit the effects that the electromagnetic interference
(EMI) produced by the Generator may have on the performance of other
equipment. Check the compatibility and safety of combinations of other
physiological monitoring and electrical apparatus to be used on the patient
in addition to the Generator.
Adequate filtering must be used to allow continuous monitoring of the surface
electrocardiogram (ECG) during radiofrequency power applications.
During power delivery, the patient should not be allowed to come in contact
with ground metal surfaces.
In order to prevent the risk of ignition make sure that flammable material is
not present in the room during RF power application.
ADVERSE EVENTS
PRODUCT SPECIFICATIONS
RFX-BAY-TS
Black at device end, blue at generator end
10 feet (3m)
4-pin (Plug)
4-pin (receptacle)
INSPECTION PRIOR TO USE
KEY ITEMS
QUESTION?
The Reusable RFP-100A connector cable is supplied
Is the
sterile for its initial use. Inspect the packaging to
Sterility
connector
ensure the package has not been damaged and
cable sterile?
sterility has not been compromised. Prior to each
subsequent use it must be cleaned and sterilized.
Have you
Ensure connectors and the cable have no visible
done a visual
damage, such as discoloration, cracks, label fading,
check on the
cable splice, or kinks. Do not use damaged
entire
equipment.
system?
EQUIPMENT REQUIRED
DIRECTIONS FOR USE
Connect the generator connector end of the cable to the isolated patient
connector port on the RFP-100A Generator as per the Generator Instructions
for Use. The generator connector end of the cable can be identified by the
blue strain relief (the device connector end has a black strain relief). The
Reusable RFP-100A connector cable uses a circular connector, keyed for
proper alignment. Gently line up the connector pins with the socket and push
in until the connector fits firmly into the socket. Any attempt to connect the
cable otherwise will damage the pins on the connector.
Do not use excessive force in connecting the cable to the generator. Use of
excessive force may result in damage to the connector pins.
Connect the device connector end of the cable to the RF Puncture Device.
The Reusable RFP-100A connector cable uses a circular connector, keyed
for proper alignment. Gently line up the connector pins with the RF Puncture
Device connector and push in until the connector fits firmly into the plug.
To disconnect the puncture device from the Connector Cable: Firmly grasp
the catheter connector (receptacle) end of the cable in one hand and gently
pull it straight out of the device connector.
To disconnect the cable from the generator, grasp the connector firmly and
gently pull it straight out of the socket.
DMR RFX 3.3 V-9.01 03-Apr-2020
WARNINGS AND EXPLANATIONS

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Baylis Medical RFP-100A

  • Página 1 Have you Ensure connectors and the cable have no visible The dimensions for the Reusable RFP-100A connector cable can be found on the done a visual damage, such as discoloration, cracks, label fading, device label and in section VII “Product Specifications.”...
  • Página 2 CLEANING AND STERILIZATION INSTRUCTIONS Consult Instructions for Use Caution DANGER The Reusable RFP-100A Connector Cable is supplied sterile, however it must be Model number Lot Number cleaned and sterilized before each subsequent use as described in this Instructions Keep Away From for Use document.
  • Página 3 VII, intitulée « Spécification du produit ». est en bon état de marche. Réalisez ces tests dans un environnement stérile. Le câble de connexion réutilisable RFP-100A est muni, à une extrémité, d’un N’utilisez pas d’équipement défectueux.
  • Página 4 RFP-100A. Les câbles de date d’envoi, pour les accessoires. connexion RFP-100A à usage unique ne sont pas conçus pour être stérilisés de Cette garantie limitée ne s’applique qu’aux nouveaux produits originaux nouveau. Aucune autre méthode de nettoyage et de stérilisation n’a été testée. Le provenant directement de l’usine et qui ont été...
  • Página 5: Contraindicaciones

    Esterilizació ¿Es estéril el Inspeccione el empaquetado para asegurarse de clavijas que se acopla al RFP-100A Generator y un conector en el otro extremo, cable conector? que el paquete no está dañado y la esterilización que se acopla al dispositivo de perforación.
  • Página 6: Resolución De Problemas

    INDICAÇÕES DE UTILIZAÇÃO distribuidor. A utilização a que se destina o Cabo conector RFP-100A reutilizável é conectar o GARANTÍA LIMITADA – Desechables y accesorios Gerador RFP-100A a dispositivos de punção aprovados de Baylis Medical Baylis Medical Company Inc.
  • Página 7 O Cabo conector RFP-100A reutilizável só pode ser usado com o Gerador Assim que o dispositivo de punção por RF estiver corretamente posicionado no RFP-100A e os dispositivos de punção por RF. As tentativas de o usar com local da punção, e o Gerador estiver corretamente configurado (seguindo as outros Geradores de RF e dispositivos podem resultar em eletrocussão do...
  • Página 8: Resolução De Problemas

    Verifique se as chaves do conector estão conetor não concebidos para se alinhadas na orientação adequada. Os períodos de garantia para produtos de Baylis Medical são os seguintes: pode ser conectarem de uma Certifique-se de que os conectores estão Produtos Descartáveis...
  • Página 9 RFP-100A aansluitkabel heeft een aansluiting met vier pinnen aan het ene uiteinde 100A wordt steriel geleverd voor het eerste die in de RFP-100A generator past en een aansluiting aan het andere uiteinde, die Is de gebruik. Controleer de verpakking om er zeker in het punctiehulpmiddel past.
  • Página 10: Beperkte Garantie

    PRODUCTEN gebruik en accessoires vrij zijn van materiaal- en verwerkingsfouten. Als u problemen heeft met of vragen heeft over apparatuur van Baylis Medical, garandeert dat steriele producten steriel blijven voor een periode die op het etiket neem dan contact op met onze technische ondersteuning.
  • Página 11 VII “Specifiche del prodotto”. Il cavo di Avete connessione riutilizzabile RFP-100A presenta a un'estremità un connettore a effettuato un Verificare che i connettori e il cavo non abbiano danni quattro pin che si accoppia con il generatore RFP-100A e all'altra estremità un Controllo controllo visibili, come...
  • Página 12: Risoluzione Dei Problemi

    NOTA: O QUALCOSA DI SIMILE (CHE SIA DIRETTO O INDIRETTO DI NATURA) O Per il cavo di connessione RFP-100A riutilizzabile sono stati validati solo i metodi QUALSIASI ALTRO TIPO DI DANNO INCIDENTALE O INDIRETTO SARÀ COPERTO. di pulitura e sterilizzazione di cui sopra. I cavi di connessione monouso RFP-100A LA RESPONSABILITÀ...
  • Página 13 RFP-100A Generators beschrieben, an dem isolierten Patientensteckeranschluss des Anschlusskabel oder Zusatzgerät zu benutzen, bevor Sie die zugehörige RFP-100A Generators an. Der Stecker des Kabels, der an dem Generator Bedienungsanleitung durchgelesen haben. angeschlossen werden muss, ist an der blauen Zugentlastung erkennbar •...
  • Página 14: Fehlersuche Und -Behebung

    Anweisungen von PRODUKTRÜCKGABE BMC gewartet wurden. Wenn Sie Probleme mit oder Fragen zu Produkten von Baylis Medical haben, HAFTUNGSAUSSCHLUSS UND EINSCHRÄNKUNG DER HAFTBARKEIT DIE kontaktieren Sie bitte Ihren Ansprechpartner vom Technischen Support. OBEN BESCHRIEBENE EINGESCHRÄNKTE...

Este manual también es adecuado para:

Rfx-bay-ts

Tabla de contenido