Functions
Same as 8
Function 9
Interval timer
Function 10
On/off, slow
Function 11
on/off and
dimmer
combination.
Momentary
Function 12
Speed control
Function 13
synchronous
(brushless)
motors.
LD1 will flash at an interval a number of times if the module
detects an irregularity during the self-test.
Remove all connections and re-establish them if the
module malfunctions. Send the module to your dealer for
repairs if it still doesn't work properly.
8
Same as Function 8, but no memory.
As long as the button is pushed, the unit will toggle between
ON and OFF (blinking). DELAY1* sets ON-time, DELAY2*
sets OFF time.
Application: Signs, alarms, disco, ...
On/off : A short push toggles between max. intensity and the
'OFF'-state.
Slow on/off : Push button for 3s to activate slow on mode.
Intensity gradually increases to max. level.
reverses the dimming action. Prolonged pushing turns off.
Dimmer : During 'OFF'-state, press button. Intensity now
continuously increases to max. level and decreases to 'OFF'.
Release button to maintain actual level. A short push turns off.
Application: When different operating modes are required
Max. intensity as long as the button is pushed.
mode
turn off.
Application: external control by e.g. timer
Push repeatedly to select OFF, 40%°, 60%°, 75%° and 100%
for
of nominal speed . To ensure startup of the motor full power is
applied for 2s after first push. °Actual speed depends on
applied motor.
Application: Speed control of a brushless fan. (e.g. Ventilator)
A brief push
Release to