3. Coverage Pattern
Refer to the illustration on page 2 of this manual.
4. PCB Description
Refer to the illustrations on page 2 of this manual.
4.1
ALARM
This is the alarm relay output contact of the detector. It is
selectable as NC or NO via the alarm jumper to match the
requirements of the protection zone.
DC12V
Connect the positive (+) side to an 8V ~ 16V DC power source,
usually from the alarm control panel. Connect the negative (-)
side to the common grounding point of the control panel.
TAMP NC
If a tamper switch is required, connect these terminals to a 24-
hour NC protection zone in the alarm control panel. The tamper
switch contact is closed with the detector's front cover secured
on the box. The opening of the front cover at any time will make
the contact open and send an immediate alarm signal to the
control panel.
V. 03 – 08/06/2020
not accept responsibility for any ensuing defects or
problems.
Nor Velleman nv nor its dealers can be held responsible for
any damage (extraordinary, incidental or indirect) – of any
nature (financial, physical...) arising from the possession,
use or failure of this product.
Keep this manual for future reference.
1
PCB fixing screw
alarm output
2
jumper
3
pulse mode jumper
4
LED on/off jumper
Connection Terminal Description
HAA52N
4
test/alarm
5
indicator
pyro sensor (do
6
not touch!)
connection
7
terminal block
8
tamper switch
©Velleman nv