Cleaning the tubular filter

 Clean the tubular filter at least once a week to ensure it main‐
tains the correct filtration efficiency.
Remove the tubular filter.
Rinse it under running water to remove any coarse soiling.
Use the Miele A 804 brush to clean inside the filter. Move the brush
in and out of the whole length of the tubular filter several times.
Then rinse the inside of the tube thoroughly with running water.
Remove any possible soiling from the O rings and check them for
any visible wear and tear.
Replace the tubular filter.
Then rinse the brush thoroughly under running water.
If wished, the tubular filter and the brush can be cleaned in the wash‐
er-disinfector after cleaning inside the filter with the brush. Place the
filter and the brush loose in a basket or mobile unit to do so.
The brush will suffer wear and tear and should therefore be re‐
placed every 2 to 3 years.