2 PRODUCT DESCRIPTION

This ECO® Electric heat exchanger is designed to accurately achieve the temperature desired on
your pool or spa.
You can see a detailed product parts overview on image 1.

3 INSTALLATION

This heater has many installation possibilities, but always respecting some guidelines:

3.1 POSITIONING

This heater can be installed on a horizontal surface.
Holding claps are just to be rotated to the desired alignment. Remember, holding clamps are to
be screw fixed securely to a firm flat wall or base. See images 2.
WARNING
Remember leaving sufficient clear space around the unit to ease pipe connections
and servicing.
Unit can be positioned up to 20º angle respect to the vertical. See images 3.

3.2 PIPING DETAILS

The heater is ready to connect to a 63mm (external diameter) pipe work, but adapters are
supplied to be able to connect to a 50mm (external diameter) piping system aswell.
The heater should be installed at a low point in the filtration system.
A check valve or siphon must be installed to ensure the heater from running filled of water
(Failure to comply with this requirement will be cause of out of warranty)
A by-pass is also recommended to ensure a correct water flow through the heater.
Heater must be installed after (downstream) the filter and before (upstream) chlorinator or
any other water treatment device.
ATTENTION
Heater must be installed after (downstream) the filter and before (upstream) any
water treatment device. Warranty void if not respected.
See image 4 for recommended installation.

3.3 ELECTRICAL CONNECTION

Electrical connection must be carried out by a qualified professional in accordance with
the country/regional requirements & regulations.
Remove terminals cover to make the connections, See image 5.
Install power supply cord according to images 6.
ATTENTION
Power supply must be fitted with a 30 mA. RCD (Residual-Current Device). Serious
damages may occur both to heater and installation if not respected. Warranty void if
not respected.