For maximum heating, load the fireplace with
-
3 logs measuring approximately 10 cm in
diameter (thermostat on position 8 and the
ventilation duct open normal speed).
Use this position only temporarily, to heat the
rooms following prolonged absence.
For an intermediate burn rate, reduce the
-
load : one or two logs (air thermostat on half
position).
For a long-lasting heat output with a slow
-
combustion rate, use 1 or 2 non-split logs with
a diameter superior to 16 cm (thermostat on
position 0 and the ventilation duct closed).
To get a long-lasting combustion rate, reload on a
merely burning bed of embers.
For rapid restarting of the fire, add some kindling
wood, load the logs, and only if necessary keep
the door partly open for several minutes, without
leaving the appliance unattended. Thereafter, use
the controls as per the instructions (paragraph
5.4). Doing so will accelerate the fire's recovery,
particularly if the wood is damp.
Make burn rate changes (switching from a slow
combustion rate to a normal rate for example)
before reloading the fireplace during the "live
coals" combustion phase, in order to allow the
fireplace
and
the
progressively to the change.
To avoid smoke and falling ash coming out into
the room during reloading operations, the door
should be opened with the following precautions :
Open the door partly, waits for the open
-
door suction to start, and open the door
slowly.
Using the stove in continuous mode and a slow
combustion rate, especially in milder temperature
conditions (bad draught) and with wet timber,
leads to an incomplete combustion and the
formation of tar and soot deposits :
Alternate the slow burning periods with
-
returns to normal burning.
Burning small loads is recommended.
-
After the stove has been used in slow combustion
mode, the front glass may darken because of a
slight soot deposit, this deposit will burn off (by
pyrolysis)
with
combustion rate).
The fitting of a suction moderating flap in the
connecting duct enables to control the burning,
notably slow burning, enabling long lasting
5.5.2.3 – Set fan
(Fig. 28)
- DESCRIPTION
The blower unit includes the following :
- a box
chimney
flue
to
the
next
hot
fire
heating.
- UTILIZATION
Select a speed of ventilation :
Put in heating the apparatus (see § 5.5).
For the versions with thermostat, select automatic
operation (AUTO) or manual operation (MANU)
with the selector :
- In the MANU position : the fan is switched on
and off by manual control. In this position, the
blower function can be started up immediately
and must be switched off by hand.
- In the AUTO position : the fan is operated
automatically, when the whole of the apparatus is
warm, generally during the following hour the
lighting. Its running is interrupted when the
apparatus is cold, generally at the fireplace's
adapt
extinction.
If you want the blower to be started up immediately
and then switched off automatically, select the MANU
position when lighting and then switch to the AUTO
position once the appliance is hot. The blower will
then be switched off automatically.

5.5.2.4 - Ash removal

The air used for the wood combustion goes under
the grid when the air knob control is open. This
air is also used to cool the grate. To ensure
optimum performance and to avoid damaging the
grate due to overheating, it is very important that
it not be obstructed. The grate should therefore
be cleaned regularly and the ashes removed.
Extracting the ash box.
Unlock the ash pan door. Position the end of the
poker in the hole on the ash pan door handle and
(higher
move the poker as shown in Fig. 18.
The scraper may be used to remove ash from the
grate (Fig. 17).
The ash pan, located under the grate, is easily
removed by pulling it out with the poker.
Remove periodically any ash which spilled
accidentally in the ash box compartment.
The level of ashes must never reach the cast
19
- a fan support with a 230 V 50 Hz 30 W
motor fan
- a fan shield
- a selector with two speeds and stop
- a thermostat which sets in motion the
ventilator in accordance with the fireplace's
temperature, if the selector
or II.
- a selector AUTO/MANU
. Little speed, selector in position I
. High speed, selector in position II
iron grate : de-ash every 2 to 3 days.