Installation Location - Campbell Hausfeld WG3080 Manual De Instrucciones De Operación Y Lista De Partes

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions and Parts Manual
General Safety Information (Continued)
additional saFety standards
ANSI Standard Z49.1 from American Welding Society,
550 N.W. Le June Rd. Miami, FL 33126
Safety and Health Standards
OSHA 29 CFR 1910, from Superintendent of Documents, U.S.
Government Printing Office, Washington, D.C. 20402
National Electrical Code
NFPA Standard 70, from National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269
Safe Handling of Compressed Gases in Cylinders
CGA Pamphlet P-1, from Compressed Gas Association, 1235
Jefferson Davis Highway, Suite 501, Arlington, VA 22202
Refer to Material Safety Data Sheets and manufacturers
instructions for metals, wire, coatings and cleaners.
Installation
loCation
Selecting the proper location can significantly increase
performance, reliability and life of the arc welder.
For best results locate welder in a clean and dry
u
environment. Dust and dirt in the welder retain moisture and
increase wear of moving parts.
Place welder in an area with at least twelve inches (305 mm)
u
of ventilation space at both the front and rear of unit. Keep
all obstructions out of this ventilation space.
Store welding wire in a clean, dry location with low humidity
u
to prevent oxidation.
Use a properly grounded receptacle for the welder and
u
ensure welder is the only load on power supply circuit. Refer
to chart on page 1 for correct circuit capacity.
Use of an extension cord is not recommended for electric
u
arc welding machines. Voltage drop in the extension cord
may significantly degrade performance of the welder.
4
Code for Safety in Welding and Cutting
CSA Standard W117.2, from Canadian Standards Association,
Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario,
Canada M9W 1R3
Cutting And Welding Processes
NFPA Standard 51B, from National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269
Safe Practices For Occupational And Educational Eye And
Face Protection
ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018
Assembly
torCH installation (see Figure 2)
1. Make sure unit is off and unplugged.
2. Feed the connectors for the torch switch through the hole
in the control panel. These leads are to be fed up over the
polarity studs and through the hanger on the center wall.
3. Insert the brass torch connector through the hole in the
control panel and into the drive deck. Make sure the
connector is inserted fully into the drive deck. Loosen the
torch clamp knob a few turns if the connector will not insert
fully. Tighten the torch clamp knob securely after the brass
torch connector is fully inserted.
4. Connect the torch switch connectors to the two 1/4 inch
terminals in the center wall. Polarity is not important. Make
sure these wires do not interfere with the polarity studs or
drive deck.
www.campbellhausfeld.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wg3090Wg4130

Tabla de contenido