OPERATION AND MAINTENANCE (
REMOVAL AND INSTALLATION OF SECONDARY HEPA FILTER
(PP650 POWER UNIT ONLY)
NOTE: This is a disposable HEPA filter; do not attempt to wash it since this will damage it.
This HEPA filter should be replaced every 5 years. Proceed as follow:
If installed, detach the exhaust line from the top of the unit.
Disassemble upper part from lower part top cap assembly by pushing on the 4 retaining
tabs (one by one) located on the lower part and pulling on upper part to disengage it.
NOTE: A small flat blade screwdriver can also be used to pry on the 4 retaining tabs, as
shown in illustration A at the bottom of the page.
Risk of warm surfaces and sharp edges. It is recommended to wear safety
gloves while handling this HEPA filter.
Discard the used filter and replace with a new one (part no. S10941416). Be sure to install
it with the gasket on top as shown in illustration B (at the bottom of the page), then snap in
place the upper part of the top cap. If need be, reconnect the exhaust line to the top cap.