3 - 3200 NT PROGRAMMATION
25
Cycle time setting
Cycle #1 Backwash
1.12
- 10 min
Cycle #2 Brine draw and slow rinse
1.13
- 45 min
Cycle #3 rapid rinse
1.14
- 10 min
Cycle #4 brine refill
1.15
- 8 min
Cycle #5
1.16
- not used
Cycle #6
1.17
- not used
Note: not visible if cycle #5 is set to OFF.
Relay activation start
1.18
- function cancelled
- activate the relay at regeneration
- activate the regeneration 10 minutes after the start
of the regeneration
Relay end
1.19
- Shut the relay at the end of the regeneration
- shut the relay 10 minutes after
Note: the regeneration end is the total time of all the
cycles.
Activation of the dosing pump relay
1.20
- function cancelled
- every 200 litres
- pump operation time every 200 litres
Meter size
1.21
- meter Fleck® 1"
- meter Fleck® 1 1/4"
- meter Fleck® 1 1/2"
- meter Fleck® 2"
- meter Fleck® 3"
- meter non Fleck®
Note: this stage will not be displayed if it is a
timeclock system #4 or the slave valves in a system
#6 or 7.
non Fleck® Meter
1.22
- 36.3 impulses per litre
Main power supply frequency
1.23
- 60 Hz
- 50 Hz
Program exit
[1- 10]
[2- 45]
[3- 10]
[4- - 8]
E
[5OFF]
N
G
[6OFF]
L
I
[ A r o f ]
S
[S- - 0]
H
[S- 10]
[E- 92]
[E- 20]
[ c P o f ]
[ u 2 0 0 ]
[t- 60]
[FF1.0]
[FF1.2]
[FF1.5]
[FF2.0]
[FF3.0]
[FF - -]
[F36.3]
[ L F 6 0 ]
[ L F 5 0 ]
3200 NT