7. PROGRAMMING
WARNINGS! Programming must be done when the motor is not in movement, after having correctly set the limit
switches (see page 6) and having checked the direction of rotation of the motor.
7.1 AUTOMATIC CLOSING MODE
The control includes, among its functions, the automatic closing after a set time.
The automatic closing activates by programming the pause time and by choosing the "impulse" operating mode (DIP2
in OFF). When the dead-man logic is active while closing, the automatic closing is excluded (DIP 2 in ON).
In order to program the pause time it is necessary:
1. To put DIP 5 and 6 in OFF
2. To put DIP 5 in ON. The green LED will switch off and make a short flash every second.
3. Wait for the pause time you want to program (the time must be greater than 5 seconds, for a maximum of 4
minutes)
4. After the required time replace the DIP 5 in OFF
If programming is correct, the green LED will flash quickly and then remains lit.
ADDITIONAL NOTE: The timer for automatic closer starts after the program time is finished; the counting of the
pause is notified via a short cut off of the green LED every 3 seconds.
Giving a stop command during the countdown, the timer will stop and the automatic closing is exclude.
The automatic reclosure is excluded (even if programmed) if:
• a safety system intervenes (safety stop, photocell, bar, motor thermal efficiency etc.)
• the dead-man logic is activated in closing
• a closing movement is interrupted.
7.2 CANCELLATION OF THE AUTOMATIC CLOSING MODE
This procedure clears the pause time and then excludes the automatic closing.
1. Put DIP 5 and 6 in OFF
2. Put DIP 5 in ON and within 3 seconds put it again in OFF.
If cancellation has been accomplished correctly, the red LED will flash quickly and then switch off. Then the green LED
will switch on steady.
7.3 PROGRAMMING OF WORKING TIME
The work time is the time it takes to perform a complete opening or closing operation. By performing this procedure
the board automatically learns the stroke. Without programming, the working time lasts 30 sec.
ATTENTION: During the programming procedure ensure that no obstacle activates the safety devices (photocells
or safety edges) and stops the movement of the door. If that happens, it is necessary to proceed with a new
programming cycle of the working time (close the current programming, perform the RESET and proceed with a new
cycle).
In order to program the working time, you must:
1. Test the motor phases and check that the limit switches are calibrated and connected properly! If during the
procedure the safety systems intervene, the movement of the motor stops.
2. Place the door halfway.
3. Put DIP 5 and 6 in OFF.
4. Put DIP 6 in ON. The red LED will switch on.
5. Give the opening command untill UP limit switch is reached and the door stops.
6. Give the closing command untill DOWN limit switch is reached and the door stops
7. Set DIP 6 in OFF. The red LED will switch off indicating the end of the programming procedure.
NOTE: In order to ensure the complete closing and opening under all conditions, the control unit automatically adds
4 seconds to the programmed time. All safety devices are active during the program time.
9
www.flexiforce.com