Installing A Cartridge - Audio-Technica AT-LP120-USB Instalación Y Funcionamiento

Sistema tocadiscos usb profesional con accionamiento directo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installing a Cartridge

Mechanical Assembly
1.
Unpack the cartridge and carefully remove its stylus assembly.
Place the stylus assembly out of harm's way.
Mount the new cartridge to the headshell assembly.
Use the mounting hardware supplied with the new cartridge.
Tighten the mounting screws until just snug.
Replace the stylus assembly briefly to check for mechanical
interference with the mounting hardware. The stylus assembly
should click into place. Make certain the new cartridge is properly
positioned in the headcase assembly per the manufacturer's
instructions. Again remove the stylus assembly for safekeeping.
8
Electrical Connections
1.
Four terminals at the rear of the cartridge are color coded to match
standard wiring in stereo tone arms. [See Figure 8.] Connect the
cartridge with the slip-on lugs provided on the headshell wiring.
neVeR SolDeR To CARTRIDGe TeRMInAlS! Heat applied to
the terminals will damage the internal cartridge wiring.
2.
For monaural operation, the left and right signal leads should be
connected to the monaural output terminal and the left and right
ground leads should be connected to the ground terminal.
3.
Finally, gently push the stylus onto the cartridge body being
careful not to damage the stylus. The stylus assembly should click
into place. Replace the headshell assembly onto the tone arm
taking care not to damage the stylus assembly.
(note: After replacing the cartridge, reset the tone arm balance, stylus
force and anti-skate based on the cartridge's specifications.)
Figure 8 – Electrical Connections
Right output
Left Output
(White)
left Ground
(Blue)
(Red)
Right Ground
(Green)