12.6.
WORKING MODE
On display some different kinds of screen can be shown, depending on the working state of the stove.
12.6.1.
IGNITION OF THE STOVE
In order to ignite the stove in automatic mode (only pellet, combi 1 or combi
2) it will be enough by pressing button P2 for 3 seconds. Firstly, the stove
carries out an initial check-up and continues the ignition process. After this,
the display shows different steps of the ignition process (light up, stabilization
and normal).
The maximum length of the ignition phase is 20 minutes. If after this time
there is not flame, the stove will automatically activate the alarm state and the
display will show the alarm message "Er12".
12.6.2.
STOVE IN OPERATION
Once certain smoke temperature has been reached, the hot air fan starts
working. Once the ignition phase has been finished properly, the stove enters
into "Work" mode which represents the normal operating mode.
The display shows the time, the set-point temperature and the room
temperature.
12.6.3.
ROOM TEMPERATURE REACHES TEMPERATURE FIXED BY
THE USER
In pellet mode (not in wood logs mode), when the room temperature reaches
the value fixed by the user or the smoke temperature reaches a value too
high, automatically, the stove starts working at a lower power. The stove
modulates. On display is shown the next information:
12.6.4.
BURNER CLEANING
While the stove is working normally in pellet mode, some automatic cleanings
of the burner take place in several minutes' intervals.
This cleaning lasts a few seconds and consists of cleaning the rests of pellet
placed in the burner in order to make easier the operation of the stove. When
this happens, the display will show the following messages:
12.6.5.
TURNING OFF THE STOVE
In order to ignite the thermo-stove, press button no.4 during a few seconds.
Once the stove is turned off, it starts the final cleaning phase in which the pellet feeder stops and the smoke extractor and the tangential
fan start working at maximum speed. This stage would not finish until the stove has reached the appropriate cooling temperature. When this
happens, the display will show the next messages:
Extintion in progress
12.6.6.
RE-IGNITION OF THE STOVE
When the stove is turned off it would not be possible to restart it up until some
safety time goes by and the thermo-stove is cold enough. If you try to ignite
the stove without being cold, the display will show the next messages but the
stove doesn't light up until it would be cold enough. After that, the stove will
ignite doing a normal light up cycle.
12.6.7.
STOVE TURNED OFF
On image it is shown the information of the display when the stove is off.
12.6.8.
STOVE IN ALARM STATE
When the stove has an alarm state, the display will show the following
messages.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
11:30
30º
20º
Ignition
11:30
30º
20º
Run Mode
11:30
30º
20º
Modulation
11:30
30º
20º
Cleaning On
11:30
30º
20º
Estinguish
11:30
30º
20º
Re. Progress
11:30
30º
20º
Off
40
CAROL-MIXTA