Technical Data; Accuracy; Ambient Conditions; Supply Voltage - Balluff BTL6-V11V-M-A1-S115 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL6-V11V-M-A1-S115 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-V11V-M _ _ _ _ -A1-S115
Micropulse AT Transducer in round profile housing
7

Technical data

7.1

Accuracy

The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL6-A-3800-2 or BTL6-A-3801-2
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
Other technical data could apply to special
models.
Special models are labeled with -SA on the part
label.
Resolution
Repeat accuracy, typical
Sampling rate
Dependent on nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
(nominal length = 500 mm,
magnet in the center of the stroke
range)
7.2

Ambient conditions

Operating temperature
Storage temperature
Relative humidity
Shock loading
per EN 60068-2-27
1)
Continuous shock
per EN 60068-2-29
1)
Vibration
per EN 60068-2-6
1)
Degree of protection per
IEC 60529 (when attached)
12
english
< 15 µm
< 20 µm
250 µs to 3.5 ms
≥ 0.5 ms
±200 µm
±0.04 % FS
≤ 20 ppm/K
0 °C to +70 °C
−40 °C to +100 °C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10 to 2000 Hz
IP 67
7.3

Supply voltage

Voltage, stabilized
2)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
GND to housing
7.4

Inputs/outputs

Short circuit resistance
7.5

Dimensions, weights

Housing diameter
Nominal length
Weight (depends on length) Approx. 1 kg/m
Housing material
1)
Individual specifications as per Balluff factory standard
2)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
20 to 28 V DC
≤ 0.5 V
pp
≤ 75 mA
≤ 4 A/0.5 ms
up to 36 V
up to 36 V
(supply cables only!)
500 V DC
Signal cable to GND
30 mm
≤ 4012 mm
Anodized aluminum

Publicidad

Tabla de contenido
loading